The application of extended modified Lambert Beer model for measurement of blood carboxyhemoglobin and oxyhemoglobin saturation
Authors:
Open Access
- 21 May 2014
- journal article
- Published by World Scientific Pub Co Pte Ltd in Journal of Innovative Optical Health Sciences
- Vol. 07 (03)
Abstract
This work presents the use of extended Modified Lambert Beer (MLB) model for accurate and continuous monitoring of percent blood carboxyhemoglobin (COHb) (SCO) and oxyhemoglobin (OxyHb) saturation ( SO 2 ) via a fitting procedure. This quantification technique is based on the absorption characteristics of hemoglobin derivatives in the wavelength range of 520–600 nm to give the best estimates of the required parameters. A comparison of the performance of the developed model and MLB law is made using attenuation data from Monte Carlo simulations for a two-layered skin model. The results revealed a lower mean absolute error of 0.4% in the values estimated by the developed model as compared to 10% that is given by the MLB law. This study showed that the discussed approach is able to provide consistent and accurate measurement of blood SO 2 and SCO across different skin pigmentations suggesting that it may potentially be used as an alternative means for clinical diagnosis of carbon monoxide ( CO ) poisoning.Keywords
This publication has 14 references indexed in Scilit:
- Monte Carlo simulation of spectral reflectance using a multilayered skin tissue modelOptical Review, 2010
- Rapid and accurate estimation of blood saturation, melanin content, and epidermis thickness from spectral diffuse reflectanceApplied Optics, 2010
- Using noninvasive multispectral imaging to quantitatively assess tissue vasculatureJournal of Biomedical Optics, 2007
- Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nmJournal of Physics D: Applied Physics, 2005
- Polarization discrimination for active imaging in scattering mediaOptics Communications, 1999
- Real-time method for fitting time-resolved reflectance and transmittance measurements with a Monte Carlo modelApplied Optics, 1998
- A new optimal wavelength for treatment of port wine stains?Physics in Medicine & Biology, 1995
- Light scattering in lntralipid-10% in the wavelength range of 400–1100 nmApplied Optics, 1991
- THE MELANOSOME: THRESHOLD TEMPERATURE FOR EXPLOSIVE VAPORIZATION AND INTERNAL ABSORPTION COEFFICIENT DURING PULSED LASER IRRADIATIONPhotochemistry and Photobiology, 1991
- Management of Carbon Monoxide PoisoningChest, 1990