Effect of microscope parameter and specimen thickness of spatial resolution of transmission electron backscatter diffraction
Authors:
- 18 April 2016
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 264 (1) , 34-40
Abstract
Summary: The spatial resolution of transmission electron backscatter diffraction (t‐EBSD) with a standard conventional EBSD detector was evaluated quantitatively based on the calculation of the correlation coefficient of transmission patterns which were acquired across a twin boundary in the sample of austenitic steel. The results showed that the resolution of t‐EBSD improved from tens of nanometres to below 10 nm with increasing accelerating voltage and thinning of specimen thickness. High voltage could enhance the penetration depth and reduce the scattering angle. And the thinning of specimen thickness would result in decreasing of the scattering events according to the theory of thermal diffuse scattering (TDS). In addition, the transmission patterns were found to be weak and noisy if the specimen was too thin, because of the decreasing intensity detected by the screen. Consequently, in this work, the best spatial resolution of 7 nm was achieved at 30 kV and 41 nm thickness. Moreover, the specimen thickness range was also discussed using Monte‐Carlo simulation. This approach was helpful to account for the differences of measured spatial resolutions, by t‐EBSD, of lamellas with different thickness.Keywords
Funding Information
- International Science & Technology Cooperation Project of China (2013DFG52290)
- Shanghai Technical Platform for Testing and Characterization on Inorganic Materials (14DZ2292900)
This publication has 19 references indexed in Scilit:
- Features of Transmission EBSD and its ApplicationJOM, 2013
- Nanometres‐resolution Kikuchi patterns from materials science specimens with transmission electron forward scatter diffraction in the scanning electron microscopeJournal of Microscopy, 2013
- Orientation mapping of nanostructured materials using transmission Kikuchi diffraction in the scanning electron microscopeUltramicroscopy, 2012
- Transmission EBSD from 10 nm domains in a scanning electron microscopeJournal of Microscopy, 2011
- Effect of microscopic parameters on EBSD spatial resolutionUltramicroscopy, 2011
- Factors affecting the accuracy of high resolution electron backscatter diffraction when using simulated patternsUltramicroscopy, 2010
- On the formation mechanisms, spatial resolution and intensity of backscatter Kikuchi patternsUltramicroscopy, 2007
- The characterization of low‐angle boundaries by EBSDJournal of Microscopy, 2005
- Resolution and sensitivity of electron backscattered diffraction in a cold field emission gun SEMUltramicroscopy, 1997
- Strain-field analysis acquired through correlation of X-ray radiographs of a fiber-reinforced composite laminateExperimental Mechanics, 1989