An 8-Channel Ambulatory EEG Recording IC With In-Channel Fully-Analog Real-Time Motion Artifact Extraction and Removal
- 26 June 2023
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 17 (5) , 999-1009
Abstract
We report the design, implementation, and experimental characterization of an 8-channel EEG recording IC (0.13 $\mu$ m CMOS, 12 mm $^{2}$ total area) with a channel architecture that conducts both the extraction and removal of motion artifacts on-chip and in-channel . The proposed dual-path feed-forward method for artifact extraction and removal is implemented in the analog domain, hence is needless of a DSP unit for artifact estimation, and its associated high-DR ADCs and DACs employed by the state of the art for artifact replica generation. Additionally, the presented architecture improves system's scalability as it enables channels' stand-alone operation, and yields the lowest reported channel power consumption among works featuring motion artifact detection/removal. Following an experimental study on electrode-skin interface electrical characteristics for dry electrodes in the absence and presence of motions, the paper presents the channel architecture, its detailed signal transfer function analysis, circuit-level implementation, and experimental characterization results. Our measurement results show an amplification voltage gain of 48.3 dB, a bandwidth of 300 Hz, rail-to-rail input DC offset tolerance, and 41.5 dB artifact suppression, while consuming 55 $\mu$ W per channel. The system's efficacy in EEG motion artifact suppression is validated experimentally, and system- and circuit-level features and performance metrics of the presented design are compared with the state of the art.Keywords
All Related Versions
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- CMC Microsystems
This publication has 25 references indexed in Scilit:
- Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the earScientific Reports, 2015
- An interdigitated non-contact ECG electrode for impedance compensation and signal restoration2015
- A 15-Channel Digital Active Electrode System for Multi-Parameter Biopotential MeasurementIEEE Journal of Solid-State Circuits, 2015
- A 345 µW Multi-Sensor Biomedical SoC With Bio-Impedance, 3-Channel ECG, Motion Artifact Reduction, and Integrated DSPIEEE Journal of Solid-State Circuits, 2014
- A Practical Mobile Dry EEG System for Human Computer Interfaces2013
- A 160 $\mu{\rm A}$ Biopotential Acquisition IC With Fully Integrated IA and Motion Artifact SuppressionIEEE Transactions on Biomedical Circuits and Systems, 2012
- Dry-Contact and Noncontact Biopotential Electrodes: Methodological ReviewIEEE Reviews in Biomedical Engineering, 2010
- Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks2009
- Comparison of methods for adaptive removal of motion artifact2002
- Reducing skin potential motion artefact by skin abrasionMedical & Biological Engineering & Computing, 1978