Position-sensorless control method at low speed for permanent magnet synchronous motors using induced voltage caused by magnetic saturation
Authors:
- 1 June 2010
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2238-2243
Abstract
A new position-sensorless method has been developed for a permanent magnet synchronous motor (PMSM) drive at low speed. This method utilizes the induced voltage caused by magnetic saturation of PMSM. The rotor position can be detected by using the open phase voltage of a conventional 120-degree commutation. No harmonic injection is needed. This paper discusses the principle of the proposed method and the experimental results.Keywords
This publication has 5 references indexed in Scilit:
- PM motor sensorless position detection based on iron B-H local hysteresis2009
- Initial Rotor Position Estimation of Interior Permanent Magnet Synchronous Motor.IEEJ Transactions on Industry Applications, 2003
- Rotor position and velocity estimation for a permanent magnet synchronous machine at standstill and high speeds2002
- Implementation and position control performance of a position-sensorless IPM motor drive system based on magnetic saliencyIEEE Transactions on Industry Applications, 1998
- Sensorless control of permanent‐magnet synchronous machines at arbitrary operating points using a modified “inform” flux modelEuropean Transactions on Electrical Power, 1993