Comparison of Bioabsorbable Versus Metallic Implant Fixation for Physeal and Epiphyseal Fractures of the Distal Tibia
Authors:
- David A. PodeszwaDPDavid A. Podeszwa
- Philip L. WilsonPWPhilip L. Wilson
- Amy R. HollandAHAmy R. Holland
- Lawson A. B. CopleyLCLawson A. B. Copley
- 1 December 2008
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Pediatric Orthopaedics
- Vol. 28 (8) , 859-863
Abstract
Transepiphyseal screw fixation of displaced distal tibial epiphyseal fractures is the most common method of treatment for these intraarticular injuries. Recent literature indicates that retained transepiphyseal metallic screws cause an increase in ankle joint contact pressure, thus favoring screw removal. Our hypothesis is that bioabsorbable screw fixation is an alternative to metallic fixation, which offers similar results without the need for screw removal. This is a retrospective review of distal tibial epiphyseal ankle fractures treated with screw fixation. Two groups, those treated with bioabsorbable screw fixation (group B, n = 24) and those with metallic screw fixation (group M, n = 26), were compared (t test) for differences in clinical and radiographic outcomes. Analysis of demographic data revealed no significant differences between groups for sex, ethnicity, age, and height. Group B was significantly heavier than group M (67.4 vs 55.6 kg; P = 0.0496). Each group had a similar number of Salter-Harris types III and IV medial malleolus fractures and transitional fracture types. There was no significant difference between groups in the time from injury to fixation or in operative time. Radiographically, there were no nonunions in either group, and at final follow-up, 1 patient in group B had distal tibial joint line irregularity versus 3 in group M. Clinically, there were no significant differences between groups in time to full weight bearing or time to full activities.There were fewer complications in group B. A single case of loss of reduction requiring revision fixation occurred in each group. There was one documented growth arrest in group M and 2 suspected growth arrests in each group. Two patients in group M were successfully treated for a superficial wound infection with oral antibiotics. Fourteen patients in group M underwent planned screw removal. Bioabsorbable screw fixation can be used for distal tibial epiphyseal fractures with no increase in operative time, nonunion rate, number of unplanned secondary surgeries, or other complications. The use of bioabsorbable screws eliminates the need for epiphyseal screw removal. A prospective randomized study is planned to eliminate the potential selection bias and to standardize clinical and radiographic follow-up. Level III, case-control study.Keywords
This publication has 33 references indexed in Scilit:
- A Biomechanical Comparison of Initial Fixation Strength of 3 Different Methods of Anterior Cruciate Ligament Soft Tissue Graft Tibial FixationThe American Journal of Sports Medicine, 2007
- Bioabsorbable Anterior Cervical PlatingSpine, 2007
- Biomechanical Stability of Bioabsorbable Screws for Fixation of Acetabular OsteotomiesJournal of Pediatric Orthopaedics, 2007
- Magnetic Resonance Imaging Analysis of Bioabsorbable Interference Screws Used for Fixation of Bone-Patellar Tendon-Bone Autografts in Endoscopic Reconstruction of the Anterior Cruciate LigamentThe American Journal of Sports Medicine, 2006
- Ankle Joint Biomechanics Following Transepiphyseal Screw Fixation of the Distal TibiaJournal of Pediatric Orthopaedics, 2005
- Transphyseal Bioabsorbable Screws Cause Temporary Growth Retardation in Rabbit FemurJournal of Pediatric Orthopaedics, 2005
- Distal tibiofibular syndesmosis fixation: A cadaveric, simulated fracture stabilization study comparing bioabsorbable and metallic single screw fixationThe Journal of Foot and Ankle Surgery, 2005
- Strength comparison of allogenic bone screws, bioabsorbable screws, and stainless steel screw fixationThe Journal of Foot and Ankle Surgery, 2002
- Bone changes after experimental osteotomies fixed with absorbable self-reinforced poly-l-lactide screws or metallic screws studied by plain radiographs, quantitative computed tomography and magnetic resonance imagingBiomaterials, 1995
- Cortical porosis under plates. Reaction to unloading or to necrosis?Journal of Bone and Joint Surgery, 1994