Parallel-plate chambers as radiation-hard detectors for time-based beam diagnostics in carbon-ion radiotherapy
Authors:
- Min Cheol HanMHMin Cheol Han
Preprint
Abstract
Accurate range verification of carbon ion beams is critical for the precision and safety of charged particle radiotherapy. In this study, we evaluated the feasibility of using a parallel-plate ionization chamber for real-time, time-based diagnostic monitoring of carbon ion beams. The chamber featured a 0.4 mm gas gap defined by metallic electrodes and was filled with carbon dioxide (CO$_2$), a non-polymerizing gas suitable for high-rate applications. Timing precision was assessed via self-correlation analysis, yielding a precision approaching one picosecond for one-second acquisitions under clinically relevant beam conditions. This level of timing accuracy translates to a water-equivalent range uncertainty of approximately 1 mm, which meets the recommended clinical tolerance for carbon ion therapy. Furthermore, the kinetic energy of the beam at the synchrotron extraction point was determined from the measured orbital period, with results consistently within 1 MeV/nucleon of the nominal energy. These findings demonstrate the potential of parallel-plate chambers for precise, real-time energy and range verification in clinical carbon ion beam quality assurance.Keywords
All Related Versions
This publication has 14 references indexed in Scilit:
- Performance studies of RPC detectors operated with C2H2F4 and CO2 gas mixturesNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2023
- Analysis of delivery and recalculation of dose using DICOM treatment recordsRadiation Medicine and Protection, 2022
- Carbon Ion Therapy: A Review of an Advanced TechnologyProgress in Medical Physics, 2020
- Characterization of a MLIC Detector for QA in Scanned Proton and Carbon Ion BeamsInternational Journal of Particle Therapy, 2019
- AAPM task group 224: Comprehensive proton therapy machine quality assuranceMedical Physics, 2019
- Survey of physical modelling in Resistive Plate ChambersJournal of Instrumentation, 2013
- Acceleration of heavy ions with a new RF system at HIMAC synchrotronNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, 2011
- Task Group 142 report: Quality assurance of medical acceleratorsa)Medical Physics, 2009
- Quality Assurance of Radiotherapy in Cancer Treatment: Toward Improvement of Patient Safety and Quality of CareJapanese Journal of Clinical Oncology, 2008
- Dynamic intensity control system with RF-knockout slow-extraction in the HIMAC synchrotronNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007