A two-degree-of-freedom motor-powered gait orthosis for spinal cord injury patients
Authors:
- 1 June 2007
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 221 (6) , 629-639
Abstract
A number of orthoses have been developed to restore stance and walking in paraplegic subjects. Compliance, however, has been limited, mainly owing to walking effort. Use of the forces produced by actuators is an effective way to solve the problem of the considerable effort required for orthotic gait, namely high muscular effort and high energy expenditure. The purpose of the present study was to investigate the effects of assistance by external actuators on the orthotic gait of spinal cord injury (SCI) patients. Two kinds of linear actuator were developed by using direct current (d.c.) motors for assisting the knee and hip joint of a gait orthosis. They were mounted on the knee and hip joint of a commercial advanced reciprocating gait orthosis (ARGO), and a new two-degree-of-freedom externally powered gait orthosis was thus developed. The orthosis was assessed through inter-subject experiments on five male adult complete SCI patients. Owing to the short training period available for the assisted gait, simultaneous operation of both joint actuators was not conducted: either the knee actuation or the hip actuation was executed only. Thus, the knee actuator and the hip actuator were assessed with a T12 subject and with subjects for T5, T8, T11, and T12 respectively. The motions of the gaits, assisted by the linear actuators, were measured by a Vicon 370 system, and the general gait parameters and compensatory motions were evaluated. Results demonstrated that (a) all subjects could walk without falling, assisted either by the knee or the hip actuator; (b) both the knee and hip joint actuator increased the gait speed and the step length; (c) the knee flexion produced by the orthosis improved the dynamic cosmesis of walking; and (d) lateral compensatory motions as well as vertical ones tended to decrease when the hip joint was assisted, which could contribute to a reduction in walking effort.Keywords
This publication has 23 references indexed in Scilit:
- Energy expenditure during walking with weight-bearing control (WBC) orthosis in thoracic level of paraplegic patientsSpinal Cord, 2003
- A knee and ankle flexing hybrid orthosis for paraplegic ambulationMedical Engineering & Physics, 2003
- Locomotor activity in spinal man: significance of afferent input from joint and load receptorsBrain, 2002
- A reliable gait phase detection systemIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2001
- Driven gait orthosis for improvement of locomotor training in paraplegic patientsSpinal Cord, 2001
- One year follow up of spinal cord injury patients using a reciprocating gait orthosis: Preliminary reportSpinal Cord, 2000
- The use of an advanced reciprocating gait orthosis by paraplegic individuals: a follow-up studySpinal Cord, 1997
- Further Development of Hybrid Functional Electrical Stimulation OrthosesArtificial Organs, 1997
- Effects of joint motion constraints on the gait of normal subjects and their implications on the further development of hybrid fes orthosis for paraplegic personsJournal of Biomechanics, 1996
- Hybrid System for Upright Mobility with Unlockable Orthotic Knee for Knee Bending during Swing Phase1996