Electrochemical Sensor of Ciprofloxacin on Screen-Printed Electrode Modified with Boron-Doped Diamond Nanoparticles and Nickel Oxide Nanoparticles Biosynthesized Using Spatholobus littoralis Hassk. Root Extract
Authors:
- Laurencia Gabrielle SutantoLSLaurencia Gabrielle Sutanto
- Prastika Krisma JiwantiPJPrastika Krisma Jiwanti
- Mirza Ardella SaputraMSMirza Ardella Saputra
- Mai TomisakiMTMai Tomisaki
- Nurul Mutmainah Diah OktavianiNurul Mutmainah Diah Oktaviani
- Widiastuti SetyaningsihWidiastuti Setyaningsih
- Yasuaki EinagaYEYasuaki Einaga
- Tahta AmrillahTATahta Amrillah
- Ilma AmalinaIAIlma Amalina
- Wan Jeffrey BasirunWan Jeffrey Basirun
- Qonita Kurnia AnjaniQAQonita Kurnia Anjani
Open Access
- 3 March 2026
- journal article
- research article
- Published by MDPI AG in Biosensors
- Vol. 16 (3) , 148
Abstract
Ciprofloxacin (CIP) is an antibiotic that is widely used in humans and animals. However, the compound has been detected in animal-derived products and the environment due to its extensive use, causing serious concern for public health and environmental safety. The issue raises the urgent need to develop innovative techniques to monitor CIP. Therefore, this study aims to develop a simple and sensitive CIP sensor called the boron-doped diamond nanoparticle-modified screen-printed electrode (BDD NPs/SPE) and the nickel oxide nanoparticle-modified BDD NPs/SPE (NiO NPs/BDD NPs/SPE). NiO NPs were synthesized via green synthesis using Spatholobus littoralis Hassk. root extract as the reducing agent. The formation and characteristics of NiO NPs were then confirmed through a UV-Vis spectrophotometer, XRD, PSA, FT-IR, and XPS. The successful modification of SPE was confirmed through SEM-EDX, followed by measurements using square-wave voltammetry. The results showed that the modified SPE could detect CIP over a concentration range of 0.1–100 µM and produced a low detection limit of 0.109 µM for BDD NPs/SPE and 0.054 µM for NiO NPs/BDD NPs/SPE. The proposed method was successfully applied to the determination of CIP in commercial tablets, milk, and human urine, with a satisfactory % recovery from 95 to 100%. The current study successfully developed a simple yet highly sensitive sensor that enabled robust, reliable, and efficient detection of CIP, showing its strong potential for practical applications.Keywords
Funding Information
- Universitas Airlangga (191/UN3.LPPM/PT.01.03/2024)
This publication has 56 references indexed in Scilit:
- New potent ciprofloxacin-uracil conjugates as DNA gyrase and topoisomerase IV inhibitors against methicillin-resistant Staphylococcus aureusBioorganic & Medicinal Chemistry, 2022
- A Review on Carbon‐based Electrodes for Electrochemical Sensor of Quinolone AntibioticsChemistrySelect, 2022
- Rational Design of Better Hydrogen Evolution Electrocatalysts for Water Splitting: A ReviewAdvanced Science, 2022
- Development of curcumin‐loaded Prunus armeniaca gum nanoparticles: Synthesis, characterization, control release behavior, and evaluation of anticancer and antimicrobial propertiesFood Science & Nutrition, 2021
- Electrochemical Sensors, a Bright Future in the Fabrication of Portable Kits in Analytical SystemsThe Chemical Record, 2019
- A ratiometric fluorometric ciprofloxacin assay based on the use of riboflavin and carbon dotsMicrochimica Acta, 2019
- The influence of crystallite size on the structural stability of Cu/SAPO-34 catalystsApplied Catalysis B: Environment and Energy, 2019
- Green synthesis and characterizations of Nickel oxide nanoparticles using leaf extract of Rhamnus virgata and their potential biological applicationsApplied Organometallic Chemistry, 2019
- Green synthesis of silver and gold nanoparticles from Gymnema sylvestre leaf extract: study of antioxidant and anticancer activitiesJournal of Nanoparticle Research, 2015
- Minimum required signal‐to‐noise ratio for optimal precision in HPLC and CEElectrophoresis, 2012