Study on the spatial resolution of EEG - effect of electrode density and measurement noise
Authors:
- J. HyttinenJHJ. Hyttinen
- J. MalmivuoJMJ. Malmivuo
- 3 February 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 4, 4409-4412
Abstract
The spatial resolution of electroencephalography (EEG) is studied by means of inverse cortical EEG solution. Special attention is paid to the effect of electrode density and the effect of measurement noise on the spatial resolution. A three-layer spherical head model is used as a volume conductor to obtain the source-field relationship of cortical potentials and scalp potential field. Effect of measurement noise is evaluated with truncated singular value decomposition (TSVD). Also simulations about different electrode systems' ability to separate cortical sources are performed. The results show that as the measurement noise increases the advantage of dense electrode systems decreases. Our results suggest that in clinical measurement environment it is always beneficial to use at least 64 measurement electrodes. In low-noise realistic measurement environment the use of even 256 measurement electrodes is beneficial.Keywords
This publication has 10 references indexed in Scilit:
- Effect of Skull Resistivity on the Spatial Resolutions of EEG and MEGIEEE Transactions on Biomedical Engineering, 2004
- Epileptic source localization with high density EEG: how many electrodes are needed?Clinical Neurophysiology, 2003
- Filtering characteristics of the human body and reconstruction limits in the inverse problem of electrocardiography2002
- Monte Carlo simulation studies of EEG and MEG localization accuracyHuman Brain Mapping, 2002
- The conductivity of the human skull: results of in vivo and in vitro measurementsIEEE Transactions on Biomedical Engineering, 2000
- Effect of EEG Electrode Density on Dipole Localization Accuracy Using Two Realistically Shaped Skull Resistivity ModelsBrain Topography, 2000
- A software implementation for detailed volume conductor modelling in electrophysiology using finite difference methodComputer Methods and Programs in Biomedicine, 1999
- Validation of a detailed computer model for the electric fields in the brainJournal of Medical Engineering & Technology, 1995
- High resolution EEG: 124-channel recording, spatial deblurring and MRI integration methodsElectroencephalography and Clinical Neurophysiology, 1994
- Seeing through the skull: Advanced EEGs use MRIs to accurately measure cortical activity from the scalpBrain Topography, 1991