Radiostereometric analysis and clinical outcomes of a novel reverse total hip system at two years
Open Access
- 24 May 2023
- journal article
- research article
- Published by British Editorial Society of Bone & Joint Surgery in Bone & Joint Open
- Vol. 4 (5) , 385-392
Abstract
Aims: Instability is a common cause of failure after total hip arthroplasty. A novel reverse total hip has been developed, with a femoral cup and acetabular ball, creating enhanced mechanical stability. The purpose of this study was to assess the implant fixation using radiostereometric analysis (RSA), and the clinical safety and efficacy of this novel design.Methods: Patients with end-stage osteoarthritis were enrolled in a prospective cohort at a single centre. The cohort consisted of 11 females and 11 males with mean age of 70.6 years (SD 3.5) and BMI of 31.0 kg/m2 (SD 5.7). Implant fixation was evaluated using RSA as well as Western Ontario and McMaster Universities Osteoarthritis Index, Harris Hip Score, Oxford Hip Score, Hip disability and Osteoarthritis Outcome Score, 38-item Short Form survey, and EuroQol five-dimension health questionnaire scores at two-year follow-up. At least one acetabular screw was used in all cases. RSA markers were inserted into the innominate bone and proximal femur with imaging at six weeks (baseline) and six, 12, and 24 months. Independent-samples t-tests were used to compare to published thresholds.Results: Mean acetabular subsidence from baseline to 24 months was 0.087 mm (SD 0.152), below the critical threshold of 0.2 mm (p = 0.005). Mean femoral subsidence from baseline to 24 months was -0.002 mm (SD 0.194), below the published reference of 0.5 mm (p < 0.001). There was significant improvement in patient-reported outcome measures at 24 months with good to excellent results.Conclusion: RSA analysis demonstrates excellent fixation with a predicted low risk of revision at ten years of this novel reverse total hip system. Clinical outcomes were consistent with safe and effective hip replacement prostheses.Cite this article: Bone Jt Open 2023;4(5):385–392.Keywords
This publication has 27 references indexed in Scilit:
- Porous titanium construct cup compared to porous coated titanium cup in total hip arthroplasty. A randomised controlled trialInternational Orthopaedics, 2014
- Early proximal migration of cups is associated with late revision in THAActa Orthopaedica, 2012
- Revision for Recurrent InstabilityThe Journal of Arthroplasty, 2011
- The Visual Analogue WOMAC 3.0 scale - internal validity and responsiveness of the VAS versionBMC Musculoskeletal Disorders, 2010
- Prospective, Randomized Comparison of Cobalt-Chrome and Titanium Trilock Femoral StemsThe Journal of Arthroplasty, 2009
- The use of the Oxford hip and knee scoresThe Journal of Bone and Joint Surgery. British volume, 2007
- The Long-term Outcome of 755 Consecutive Constrained Acetabular Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Effect of augmented cup fixation on stability, wear, and osteolysis: A 5-year follow-up of total hip arthroplasty with RSAThe Journal of Arthroplasty, 2004
- Biomechanics of Large Femoral HeadsClinical Orthopaedics and Related Research, 2004
- EuroQol - a new facility for the measurement of health-related quality of lifeHealth Policy, 1990