Comparison of the qCON and qNOX indices for the assessment of unconsciousness level and noxious stimulation response during surgery
Open Access
- 20 October 2016
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 31 (6) , 1273-1281
Abstract
The objective of this work is to compare the performances of two electroencephalogram based indices for detecting loss of consciousness and loss of response to nociceptive stimulation. Specifically, their behaviour after drug induction and during recovery of consciousness was pointed out. Data was recorded from 140 patients scheduled for general anaesthesia with a combination of propofol and remifentanil. The qCON 2000 monitor (Quantium Medical, Barcelona, Spain) was used to calculate the qCON and qNOX. Loss of response to verbal command and loss of eye-lash reflex were assessed during the transition from awake to anesthetized, defining the state of loss of consciousness. Movement as a response to laryngeal mask (LMA) insertion was interpreted as the response to the nociceptive stimuli. The patients were classified as movers or non-movers. The values of qCON and qNOX were statistically compared. Their fall times and rise times defined at the start and at the end of the surgery were calculated and compared. The results showed that the qCON was able to predict loss of consciousness such as loss of verbal command and eyelash reflex better than qNOX, while the qNOX has a better predictive value for response to noxious stimulation such as LMA insertion. From the analysis of the fall and rise times, it was found that the qNOX fall time (median: 217 s) was significantly longer (p value p value <0.05). The indices qCON and qNOX showed different performances in the detection of loss of consciousness and loss of response to stimuli during induction and recovery of consciousness. Furthermore, the qCON showed faster decrease during induction. This behaviour is associated with the hypothesis that the loss of response to stimuli (analgesic effect) might be reached after the loss of consciousness (hypnotic effect). On the contrary, the qNOX showed a faster increase at the end of the surgery, associated with the hypothesis that a higher probability of response to stimuli might be reached before the recovery of consciousness.Keywords
Funding Information
- Instituto de Salud Carlos III (PS09/01209)
- Secretaría de Estado de Investigación, Desarrollo e Innovación (PTQ-14-06978)
This publication has 40 references indexed in Scilit:
- Modeling the Effect of Propofol and Remifentanil Combinations for Sedation-Analgesia in Endoscopic Procedures Using an Adaptive Neuro Fuzzy Inference System (ANFIS)Anesthesia & Analgesia, 2011
- Noxious Stimulation Response IndexAnesthesiology, 2010
- Changes in skin conductance as a tool to monitor nociceptive stimulation and painCurrent Opinion in Anaesthesiology, 2008
- Variability Comparison of the Composite Auditory Evoked Potential Index and the Bispectral Index During Propofol-Fentanyl AnesthesiaAnesthesia & Analgesia, 2008
- Cerebral State Index during Propofol AnesthesiaAnesthesiology, 2006
- Effect of Auditory Evoked Potential Index Monitoring on Anesthetic Drug Requirements and Recovery Profile after Laparoscopic SurgeryAnesthesiology, 2003
- Propofol effective concentration 50 and its relationship to bispectral indexAnaesthesia, 2002
- Targeting Effect Compartment or Central Compartment Concentration of PropofolAnesthesiology, 1999
- Measuring the Performance of Anesthetic Depth IndicatorsAnesthesiology, 1996
- Measured Context-sensitive Half-times of Remifentanil and AlfentanilAnesthesiology, 1995