Increasing accuracy of pulse arrival time estimation in low frequency recordings
Open Access
- 1 March 2024
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 45 (3) , 03NT01
Abstract
Objective. Wearable devices that measure vital signals using photoplethysmography are becoming more commonplace. To reduce battery consumption, computational complexity, memory footprint or transmission bandwidth, companies of commercial wearable technologies are often looking to minimize the sampling frequency of the measured vital signals. One such vital signal of interest is the pulse arrival time (PAT), which is an indicator of blood pressure. To leverage this non-invasive and non-intrusive measurement data for use in clinical decision making, the accuracy of obtained PAT-parameters needs to increase in lower sampling frequency recordings. The aim of this paper is to develop a new strategy to estimate PAT at sampling frequencies up to 25 Hertz. Approach. The method applies template matching to leverage the random nature of sampling time and expected change in the PAT. Main results. The algorithm was tested on a publicly available dataset from 22 healthy volunteers, under sitting, walking and running conditions. The method significantly reduces both the mean and the standard deviation of the error when going to lower sampling frequencies by an average of 16.6% and 20.2%, respectively. Looking only at the sitting position, this reduction is even larger, increasing to an average of 22.2% and 48.8%, respectively. Significance. This new method shows promise in allowing more accurate estimation of PAT even in lower frequency recordings.Keywords
This publication has 18 references indexed in Scilit:
- Pulse arrival time as a surrogate of blood pressureScientific Reports, 2021
- Impact of the PPG Sampling Rate in the Pulse Rate Variability Indices Evaluating Several Fiducial Points in Different Pulse WaveformsIEEE Journal of Biomedical and Health Informatics, 2021
- The minimal sampling frequency of the photoplethysmogram for accurate pulse rate variability parameters in healthy volunteersBiomedical Signal Processing and Control, 2021
- A correlation study of beat-to-beat R-R intervals and pulse arrival time under natural state and cold stimulationScientific Reports, 2021
- Pulse Arrival Time and Pulse Interval as Accurate Markers to Detect Mechanical AlternansAnnals of Biomedical Engineering, 2019
- Photoplethysmography beat detection and pulse morphology quality assessment for signal reliability estimation2017
- Comparison of foot finding methods for deriving instantaneous pulse rates from photoplethysmographic signalsJournal of Clinical Monitoring and Computing, 2015
- Increasing Stability of Real-Time Pulse Wave Velocity Estimation by Combining Established and New Approaches2013
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- A database to support development and evaluation of intelligent intensive care monitoring2002