The Harvard medical practice study trigger system performance in deceased patients
Open Access
- 8 January 2019
- journal article
- research article
- Published by Springer Nature in BMC Health Services Research
- Vol. 19 (1) , 16
Abstract
To detect possible threats to quality and safety, multiple systems have been developed. One of them is retrospective chart review. A team of experts scrutinizes medical records, selected by trigger systems, to detect possible adverse events (AEs). The most important AEs and more hints for possible improvement of care appear in deceased patients. Using triggers in a sample of these patients might increase the performance and lower the burden of scrutinizing records without possible preventable AEs. The aim of this study was therefore to determine the performance of the trigger system in a sample of deceased patients and to calculate the specificity and the sensitivity of this trigger system for predicting AEs. We performed a study in which the records of deceased patients were screened for triggers by a team of trained nurses. A sample of 100 medical records was randomly selected out of records which had been screened between 2012 and 2015 for the first time, prior to the study in 2016. For the determination of significant differences between the first and second screening, McNemar’s test of symmetry was used. Also, observed agreement, Cohen’s Kappa and prevalence-adjusted and-bias-adjusted-kappa (PABAK) statistics were calculated. This was done for the two trigger rounds on both any trigger present and for every trigger separately. The observed agreement for any given trigger was 75% with a Kappa and PABAK of 0.5. For the individual triggers, the observed agreement was on average 90%. The corresponding Kappa was on average 0.42 (range: − 0.03-0.78) and the average PABAK was 0.8 (range: 0.44–0.92). Two adverse events were found in cases without triggers previously. The recalculated specificity and sensitivity for the original population were 58 and 92% respectively. For the reproducibility of triggers it seems that some perform better than others, but on average this is to our opinion suboptimal. The low specificity implies that many records are selected without AEs. This leads to a high false-positive rate making this labour-intensive record review process costly. Therefore, research for better and more expedient systems is required.Keywords
This publication has 33 references indexed in Scilit:
- Is detection of adverse events affected by record review methodology? an evaluation of the “Harvard Medical Practice Study” method and the “Global Trigger Tool”Patient Safety in Surgery, 2013
- Preventable deaths due to problems in care in English acute hospitals: a retrospective case record review studyBMJ Quality & Safety, 2012
- Patient safety in developing countries: retrospective estimation of scale and nature of harm to patients in hospitalBMJ, 2012
- ‘Global Trigger Tool’ Shows That Adverse Events In Hospitals May Be Ten Times Greater Than Previously MeasuredHealth Affairs, 2011
- Description of the development and validation of the Canadian Paediatric Trigger ToolBMJ Quality & Safety, 2011
- Performance Characteristics of a Methodology to Quantify Adverse Events over Time in Hospitalized PatientsHealth Services Research, 2010
- Adverse events and potentially preventable deaths in Dutch hospitals: results of a retrospective patient record review studyQuality and Safety in Health Care, 2009
- The incidence of adverse events in Swedish hospitals: a retrospective medical record review studyInternational Journal for Quality in Health Care, 2009
- Development and Evaluation of the Institute for Healthcare Improvement Global Trigger ToolJournal of Patient Safety, 2008
- Sensitivity of routine system for reporting patient safety incidents in an NHS hospital: retrospective patient case note reviewBMJ, 2006