Robustness and Ruggedness of Isoelectric Focusing and Superficially Porous Liquid Chromatography with Fourier Transform Mass Spectrometry
- 4 December 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in Journal of the American Society for Mass Spectrometry
- Vol. 32 (1) , 346-354
Abstract
An investigation of a multidimensional proteomics workflow composed of off-gel isoelectric focusing (IEF) and superficially porous liquid chromatography (SPLC) with Fourier transform mass spectrometry (FTMS) was completed in order to assess various figures of merit associated with intact protein measurements. Triplicate analysis performed at both high and low FTMS resolutions on the E. coli proteome resulted in ∼900 redundant proteoforms from 3 to 95 kDa. Normalization of the chromatographic axis to identified proteoforms enabled reproducible physicochemical property measurements between proteome replicates with inter-replicate variances of ±3 ppm mass error for proteoforms 30 kDa, ±12 s retention time error, and ±0.21 pI units. The results for E. coli and standard proteins revealed a correlation between pI precision and proteoform abundance with species detected in multiple IEF fractions exhibiting pI precisions less than the theoretical resolution of the off-gel system (±0.05 vs ±0.17, respectively). Evaluation of differentially modified proteoforms of standard proteins revealed that high sample loads (100s μgrams) change the IEF pH gradient profile, leading to sample broadening that facilitates resolution of charged post-translational modifications (e.g., phosphorylation, sialylation). Despite the impact of sample load on IEF resolution, results on standard proteins measured directly or after being spiked into E. coli demonstrated that the reproducibility of the workflow permitted recombination of the MS signal across IEF fractions in a manner supporting the evaluation of three label-free quantitation metrics for intact protein studies (proteoforms, proteoform ratios, and protein) over 102–103 sample amount with low femtomole detection limits.Keywords
Funding Information
- National Multiple Sclerosis Society Minnesota Chapter (PP-1503-04034)
- National Institute of General Medical Sciences (1R01GM115739-01A1)
- Friends of Alzheimer's Disease Research Award
- Texas Alzheimer?s Research and Care Consortium Investigator Grant Program (354091)
- UT System Neuroscience and Neurotechnology Research Institute (363027)
- John L. Roach Scholarship in Biomedical Research
- Darrel K. Royal Research Fund for Alzheimer?s Disease (48680-DKR)
This publication has 57 references indexed in Scilit:
- Top-Down Mass Spectrometry: Proteomics to Proteoforms2016
- Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part IAnalytica Chimica Acta, 2015
- Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part IIAnalytica Chimica Acta, 2015
- Protein post-translational modifications and regulation of pluripotency in human stem cellsCell Research, 2013
- In-depth proteomic analysis of human tropomyosin by top-down mass spectrometryJournal of Muscle Research and Cell Motility, 2013
- Proteolytic elimination of N-myristoyl modifications by the Shigella virulence factor IpaJNature, 2013
- Proteoform: a single term describing protein complexityNature Methods, 2013
- Protein Analysis by Shotgun/Bottom-up ProteomicsChemical Reviews, 2013
- Comprehensive Analysis of Protein Modifications by Top-Down Mass SpectrometryCirculation: Cardiovascular Genetics, 2011
- Histone modifications dictate specific biological readoutsJournal of Genetics and Genomics, 2009