Development of a temperature-controlled miniature enclosure for monitoring poor perfusion photoplethysmographic signals
- 21 August 2007
- journal article
- research article
- Published by IOP Publishing in Physiological Measurement
- Vol. 28 (9) , N67-N75
Abstract
A major issue in most optical-based physiological measurements is the effect of temperature fluctuations on the reliability of the acquired data. Studies have suggested that waveforms obtained from the photoplethysmography (PPG) method are temperature sensitive. The conventional approach to tackle these temperature induced variations is to post-signal process the waveforms in the hope of optimizing them to a minimum level for signal pattern and recognition. However, it is known such an approach may alter the PPG characteristics which can be used to identify the pathogenesis and/or pathophysiology of peripheral vascular diseases. Thus, appropriate temperature settings can then facilitate prolonged comparative clinical studies and minimize pathogenic survivability. In this study, a miniature enclosure with a temperature-control feature is proposed to enhance PPG acquisition in a more consistent environment. Eight healthy adults (six male; 26.4 +/- 3.0 yr) were recruited to perform three different test trials to assess the usefulness of the proposed system. The obtained results indicated that without the activation of the temperature-control feature, PPG characteristics acquired from cold fingers can be compromised. Conversely, improvements can be observed when the temperature feature was activated. Hence, the findings herein suggest that this system can be a valuable tool in acquiring PPG waveforms from poorly perfused fingers.Keywords
This publication has 17 references indexed in Scilit:
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Mechanism of bacterial adaptation to low temperatureJournal of Biosciences, 2006
- A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion statesMedical & Biological Engineering & Computing, 2006
- Modeling thermal damage in skin from 2000-nm laser irradiationJournal of Biomedical Optics, 2006
- Characterization of bioactive surface oxidation layer on NiTi alloyApplied Surface Science, 2005
- Photoplethysmography detection of lower limb peripheral arterial occlusive disease: a comparison of pulse timing, amplitude and shape characteristicsPhysiological Measurement, 2005
- Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signalsPhysiological Measurement, 2005
- Autonomic Function Interferes in Cardiovascular ReflexesArchives of Medical Research, 2003
- Local Cold Exposure Test with a New Arterial Photoplethysmographic Sensor in Healthy Controls and Patients with Secondary Raynaud's PhenomenonMicrovascular Research, 1999
- Development of a neural network screening aid for diagnosing lower limb peripheral vascular disease from photoelectric plethysmography pulse waveformsPhysiological Measurement, 1993