Automatic radiotherapy delineation quality assurance on prostate MRI with deep learning in a multicentre clinical trial
- 28 September 2021
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (19) , 195008
Abstract
Volume delineation quality assurance (QA) is particularly important in clinical trial settings where consistent protocol implementation is required, as outcomes will affect future as well current patients. Currently, where feasible, this is conducted manually, which is time consuming and resource intensive. Although previous studies mostly focused on automating delineation QA on CT, magnetic resonance imaging (MRI) is being increasingly used in radiotherapy treatment. In this work, we propose to perform automatic delineation QA on prostate MRI for both the clinical target volume (CTV) and organs-at-risk (OARs) by using delineations generated by 3D Unet variants as benchmarks for QA. These networks were trained on a small gold standard atlas set and applied on a multicentre radiotherapy clinical trial dataset to generate benchmark delineations. Then, a QA stage was designed to recommend ‘pass’, ‘minor correction’ and ‘major correction’ for each manual delineation in the trial set by thresholding its Dice similarity coefficient to the network generated delineation. Among all 3D Unet variants explored, the Unet with anatomical gates in an AtlasNet architecture performed the best in delineation QA, achieving an area under the receiver operating characteristics curve of 0.97, 0.92, 0.89 and 0.97 for identifying unacceptable (major correction) delineations with a sensitivity of 0.93, 0.73, 0.74 and 0.90 at a specificity of 0.93, 0.86, 0.86 and 0.95 for bladder, prostate CTV, rectum and gel spacer respectively. To the best of our knowledge, this is the first study to propose automated delineation QA for a multicentre radiotherapy clinical trial with treatment planning MRI. The methods proposed in this work can potentially improve the accuracy and consistency of CTV and OAR delineation in radiotherapy treatment planning.Keywords
Funding Information
- National Health and Medical Research Council (NHMRC) Project Grant ‘Reducing the greatest uncertainty in radiotherapy’ (1102198)
This publication has 27 references indexed in Scilit:
- Automatic Substitute Computed Tomography Generation and Contouring for Magnetic Resonance Imaging (MRI)-Alone External Beam Radiation Therapy From Standard MRI SequencesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2015
- Radiotherapy planning using MRIPhysics in Medicine & Biology, 2015
- Technical quality assurance during the TROG 03.04 RADAR prostate radiotherapy trial: Are the results reflected in observed toxicity rates?Journal of Medical Imaging and Radiation Oncology, 2014
- The Impact of Peer Review of Volume Delineation in Stereotactic Body Radiation Therapy Planning for Primary Lung Cancer: A Multicenter Quality Assurance StudyJournal of Thoracic Oncology, 2014
- Structure-Guided Nonrigid Registration of CT–MR Pelvis Scans with Large Deformations in MR-Based Image Guided Radiation Therapy2014
- Improving radiotherapy quality assurance in clinical trials: assessment of target volume delineation of the pre-accrual benchmark caseBritish Journal of Radiology, 2013
- Quality improvements in prostate radiotherapy: Outcomes and impact of comprehensive quality assurance during the TROG 03.04 ‘RADAR’ trialJournal of Medical Imaging and Radiation Oncology, 2013
- Comparing images using the Hausdorff distanceIEEE Transactions on Pattern Analysis and Machine Intelligence, 1993
- On a Test of Whether one of Two Random Variables is Stochastically Larger than the OtherThe Annals of Mathematical Statistics, 1947
- Measures of the Amount of Ecologic Association Between SpeciesEcology, 1945