Relationship between electrical gaps after Maze procedure and atrial tachyarrhythmias and ablation outcomes after cardiac surgery and concomitant Maze procedure
Authors:
- 13 February 2021
- journal article
- research article
- Published by Springer Nature in Heart and Vessels
- Vol. 36 (5) , 675-685
Abstract
Atrial tachycardia (AT) and atrial fibrillation (AF) commonly occur after cardiac surgeries (CSs). This study investigated the mechanisms and long-term outcomes of AT and AF ablation after various Maze procedures, particularly whether atrial tachyarrhythmias after the Maze procedure occur due to gaps in the Maze lines. We analyzed 37 consecutive cases with atrial tachyarrhythmias after the Maze procedures and concomitant CSs between 2007 and 2019. Fifty-nine atrial tachyarrhythmias were induced in 37 consecutive cases, and 49 of those atrial tachyarrhythmias were mappable ATs. Forty ATs were related to the Maze procedures in the 49 mappable ATs (81.6%). All 37 consecutive cases had residual electrical conductions (gaps) in the Maze lines (88 gaps; 2.4 ± 1.2 gaps/patient). Forty of 88 gaps (45.5%) were associated with gap-related ATs. The common ATs in this study were 1. peri-mitral atrial flutter due to gaps at pulmonary vein isolation (PVI) line to mitral valve annulus (MVA) (20 cases), and 2. peri-tricuspid atrial flutter due to gaps at right atrial incision to the tricuspid valve annulus (TVA) (10 cases). Forty-seven of 49 ATs (95.9%) were successfully ablated at the first session, and there were no complications. The mean follow-up period after ablation was 3.6 ± 3.2 (median, 2.1; interquartile range, 0.89–6.84) years. The Kaplan–Meier analysis of freedom from recurrent atrial tachyarrhythmias after Maze procedure was 82.7% at 1-year follow-up and 75.5% at 4-year follow-up after a single procedure. Reentry was the main mechanism of ATs after Maze procedures and concomitant CSs, and ATs were largely related to the gaps on the Maze lines between the PVI line and the MVA or those on the lines between right atrial incision to the TVA. Long-term follow-up data suggest that catheter ablation of atrial tachyarrhythmias after various Maze procedures is effective and safe.Keywords
This publication has 28 references indexed in Scilit:
- Contemporary outcomes of the concomitant CryoMaze procedureInteractive CardioVascular and Thoracic Surgery, 2019
- Histopathological and Immunological Characteristics of Tachycardia-Induced CardiomyopathyJACC, 2017
- The Society of Thoracic Surgeons 2017 Clinical Practice Guidelines for the Surgical Treatment of Atrial FibrillationThe Annals of Thoracic Surgery, 2017
- Heart Failure and Tachycardia-Induced CardiomyopathyCurrent Heart Failure Reports, 2013
- Long-term results of the maze procedure on left ventricular function for persistent atrial fibrillation associated with mitral valve diseaseHeart and Vessels, 2011
- A prospective, single-center clinical trial of a modified Cox maze procedure with bipolar radiofrequency ablationThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Lifetime Risk for Development of Atrial FibrillationCirculation, 2004
- Microwave and radiofrequency ablation yield similar success rates for treatment of chronic atrial fibrillation1European Journal of Cardio-Thoracic Surgery, 2004
- Treatment of Atrial Fibrillation Using the Maze Procedure: The Japanese ExperienceSeminars in Thoracic and Cardiovascular Surgery, 2000
- Successful surgical treatment of atrial fibrillation. Review and clinical updateJAMA, 1991