The inter-sample structural variability of regular tissue-engineered scaffolds significantly affects the micromechanical local cell environment
Authors:
Open Access
- 6 April 2015
- journal article
- Published by The Royal Society in Interface Focus
- Vol. 5 (2) , 20140097
Abstract
Rapid prototyping techniques have been widely used in tissue engineering to fabricate scaffolds with controlled architecture. Despite the ability of these techniques to fabricate regular structures, the consistency with which these regular structures are produced throughout the scaffold and from one scaffold to another needs to be quantified. Small variations at the pore level can affect the local mechanical stimuli sensed by the cells thereby affecting the final tissue properties. Most studies assume rapid prototyping scaffolds as regular structures without quantifying the local mechanical stimuli at the cell level. In this study, a computational method using a micro-computed tomography-based scaffold geometry was developed to characterize the mechanical stimuli within a real scaffold at the pore level. Five samples from a commercial polycaprolactone scaffold were analysed and computational fluid dynamics analyses were created to compare local velocity and shear stress values at the same scaffold location. The five samples did not replicate the computer-aided design (CAD) scaffold and velocity and shear stress values were up to five times higher than the ones calculated in the CAD scaffold. In addition high variability among samples was found: at the same location velocity and shear stress values could be up to two times higher from sample to sample. This study shows that regular scaffolds need to be thoroughly analysed in order to quantify real cell mechanical stimuli so inspection methods should be included as part of the fabrication process.Keywords
This publication has 30 references indexed in Scilit:
- State of the art and future direction of additive manufactured scaffolds-based bone tissue engineeringRapid Prototyping Journal, 2014
- Scaffolds for bone tissue engineering fabricated from two different materials by the rapid prototyping technique: PCL versus PLGAJournal of Materials Science: Materials in Medicine, 2012
- Additive manufacturing of tissues and organsProgress in Polymer Science, 2012
- Rapid prototyped PGA/PLA scaffolds in the reconstruction of mandibular condyle bone defectsThe International Journal of Medical Robotics and Computer Assisted Surgery, 2009
- 3D polycaprolactone scaffolds with controlled pore structure using a rapid prototyping systemJournal of Materials Science: Materials in Medicine, 2008
- Effect of scaffold architecture and pore size on smooth muscle cell growthJournal of Biomedical Materials Research Part A, 2008
- A critical review on polymer-based bio-engineered materials for scaffold developmentComposites Part B: Engineering, 2007
- Porosity of 3D biomaterial scaffolds and osteogenesisBiomaterials, 2005
- Porous scaffold design for tissue engineeringNature Materials, 2005
- Fabrication using a rapid prototyping system and in vitro characterization of PEG-PCL-PLA scaffolds for tissue engineeringJournal of Biomaterials Science, Polymer Edition, 2005