Automatic application of teat disinfectant through the milking machine cluster
Authors:
- 1 May 1989
- journal article
- research article
- Published by Cambridge University Press (CUP) in Journal of Dairy Research
- Vol. 56 (4) , 579-585
Abstract
Summary: An automatic device, which infuses disinfectant into the mouthpiece of the liner of the milking machine cluster as teatcups are removed, is described. Application at this time avoids any delay in disinfection, reduces the workload in the parlour and increases reliability of application. The teats of 20 cows were contaminated before each milking by immersion in a suspension of Staphylococcus aureus and Streptococcus agalactiae and then disinfected manually or automatically with iodophor after milking. Str. agalactiae was recovered from < 5% of swabs and there was no difference between the results from the two methods. Neither method of disinfection was as effective against Staph. aureus and the recovery rate was significantly greater for the automatic method for both swabs from teat barrel (P < 0·05) and teat apex (P < 0·001). Rates of intramammary infection for quarters automatically or manually disinfected were similar and low (3/40 v. 6/40 respectively). The automatic method facilitates cluster removal by relieving vacuum and decreasing frictional contact at the mouthpiece lip, and utilizes approximately half the quantity of disinfectant used by manual dipping (0·9 v. 1·9 ml/teat). However, iodine contamination in the milk from the iodophor teat disinfectant was significantly increased from 14·4 to 102·2 μg I2/100 ml milk when no backflushing was practised.Keywords
This publication has 8 references indexed in Scilit:
- Effect of hydraulic milking on milking performance, teat condition and lipolysisJournal of Dairy Research, 1989
- Responses of the bovine teat to machine milking: measurement of changes in thickness of the teat apexJournal of Dairy Research, 1988
- A multi-valved milking machine cluster to control intramammary infection in dairy cowsJournal of Dairy Research, 1988
- Field Trial Evaluation of Premilking Teat DisinfectionJournal of Dairy Science, 1987
- Effect of Duration of Teat Cup Liner Closure Per Pulsation Cycle on Bovine MastitisJournal of Dairy Science, 1981
- Milk Iodine as Influenced by an lodophor Teat DipJournal of Dairy Science, 1978
- MAMMARY TISSUE INJURY RESULTING FROM IMPROPER MACHINE MILKING1964