Evolution of the Organization of Epicardial Activation Patterns During Ventricular Fibrillation
Authors:
- Jack M. RogersJRJack M. Rogers
- Dennis L. RollinsDRDennis L. Rollins
- Raymond E. IdekerRIRaymond E. Ideker
- 1 December 1998
- journal article
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 9 (12) , 1291-1304
Abstract
Activation During Ventricular Fibrillation. Introduction: This study quantified how the organization of epicardial activation changes during the first 40 seconds of ventricular fibrillation (VF). Activation During Ventricular Fibrillation. Introduction: This study quantified how the organization of epicardial activation changes during the first 40 seconds of ventricular fibrillation (VF). Methods and Results: Unipolar potentials were mapped from a 504 (24 × 21) electrode array (2‐mm interelectrode spacing) on the anterior right ventricle (RV) and left ventricle (LV) epicardium. The array covered approximately 20% of the epicardial surface. In each of seven pigs, six episodes of VF were induced by premature stimulation. One‐half second epochs of VF were analyzed, starting 0, 10, 20, 30, and 40 seconds post induction and using novel pattern analysis algorithms. Eight parameters were quantified: (1) the number of wavefronts; (2) the epicardial area activated by wavefronts; (3) the fraction of wavefronts arising from epicardial breakthrough or from a focus; (4) the fraction of wavefronts terminated by conduction block; (5) the multiplicity index (number of distinct activation pathways in the rhythm); (6) the repeatability index (number of times activation pathways are traversed); (7) the activation rate; and (8) the wavefront propagation velocity. The results showed that VF patterns were less organized at 10 than at 0 seconds, with more, smaller wavefronts traversing a larger variety of pathways for fewer repetitions. VF activation patterns then gradually reorganized up to 40 seconds, but by a different mechanism: the spatial size of subpatterns grew, but the dynamics otherwise appeared unchanged. During both transitions, both activation rate and propagation velocity slowed monotonically. Conclusion: Thus, changes in organization during VF can occur by multiple mechanisms.Keywords
This publication has 31 references indexed in Scilit:
- Tedisamil increases coherence during ventricular fibrillation and decreases defibrillation energy requirementsCardiovascular Research, 1997
- An Automated Technique for Identification and Analysis of Activation Fronts in a Two-Dimensional Electrogram ArrayComputers and Biomedical Research, 1994
- A Quantitative Measurement of Spatial Orderin Ventricular FibrillationJournal of Cardiovascular Electrophysiology, 1993
- Efficient electrode spacing for examining spatial organization during ventricular fibrillationIEEE Transactions on Biomedical Engineering, 1993
- Cardiac Sympathetic Nervous Activity during Myocardial Ischemia, Reperf usion and Ventricular Fibrillation in the Dog - Effects of Intravenous LidocaineCardiology, 1992
- A Cellular Automaton Model of Excitable Media Including Curvature and DispersionScience, 1990
- Mechanoelectrical feedback: independent role of preload and contractility in modulation of canine ventricular excitability.Journal of Clinical Investigation, 1985
- The transition to ventricular fibrillation induced by reperfusion after acute ischemia in the dog: a period of organized epicardial activation.Circulation, 1981
- Effect of acute coronary artery occlusion on local myocardial extracellular K+ activity in swine.Circulation, 1980
- Studies of ventricular fibrillation caused by electric shockAmerican Heart Journal, 1930