Effect of Elbow Flexion on the Proximity of the PIN During 2-incision Distal Biceps Repair
Authors:
- Jason A. JonesJJJason A. Jones
- Christopher M. JonesCJChristopher M. Jones
- Mark G. GrossmanMGMark G. Grossman
- 1 July 2013
- journal article
- Published by SLACK, Inc. in Orthopedics
- Vol. 36 (7)
Abstract
Feature Article Jason A. Jones, MD; Christopher M. Jones, MD; Mark G. Grossman, MD The posterior interosseous nerve (PIN) is at risk for injury during surgical dissection for distal biceps repair, yet the optimal position of elbow flexion to avoid a PIN injury has never been established for the 2-incision approach. The purpose of this study was to determine the proximity of the PIN to the radial tuberosity during surgical dissection in different degrees of elbow flexion. Ten cadaveric specimens with an intact elbow and forearm were dissected in full pronation using a modified Boyd-Anderson approach. Half of the dissections were completed in 90° of flexion and the other half were completed in maximal flexion. To simulate the location of the PIN during a single-incision biceps repair, the distance of the PIN to the radial tuberosity was recorded in full extension and supination. Results from these measurements were assessed for differences using paired t tests, with differences deemed significant for P values less than .05. The PIN was not identified in any of the 2-incision surgical dissections. Based on these findings, the proximity of the PIN to the radial tuberosity is not significantly affected by the degree of elbow flexion in the muscle-splitting 2-incision approach. In addition, a safe zone exists for avoiding PIN injury in a single-incision technique for distal biceps repair because a drill bit exiting the radial tuberosity greater than 1 cm in a distal-radial direction would place the PIN at risk. The authors are from the Department of Orthopaedic Surgery (JAJ), Lenox Hill Hospital, New York; the Department of Orthopaedics (CMJ, MGG), SUNY at Stony Brook University Medical Center, Stony Brook; and the Division of Orthopaedic Sports Medicine (MGG), Winthrop Unviersity Hospital, Mineola, New York. The authors have no relevant financial relationships to disclose. The authors thank David E. Komatsu, PhD, for his statistical analysis and expertise. Correspondence should be addressed to: Jason A. Jones, MD, Department of Orthopaedic Surgery, Lenox Hill Hospital, 100 E 77th St, New York, NY 10075 (cmjhoya@gmail.com). Rupture of the distal biceps tendon from the radial tuberosity occurs when an eccentric load is rapidly applied at the elbow, such as during lifting or catching activities. It is common in middle-aged men, highly active individuals, and smokers, with an incidence of 1.2 per 100,000.1–3 Rupture of the distal biceps weakens the elbow in flexion and supination and can be debilitating. Results from surgical repair have been superior to those from nonsurgical treatment with respect to supination strength, flexion strength, and upper-extremity endurance.1,3–5 The preferred surgical approach remains an area of debate; both single- and 2-incision techniques have been used with successful outcomes and minimal complications.6 Historically, repair of the distal biceps was performed through an extensile anterior, or Henry, approach. To minimize the relatively high rate of neurologic injury associated with the Henry approach, a 2-incision technique was developed by Boyd and Anderson.7 This approach was later modified by Kelly et al8 to split the extensor muscles, which seems to lessen the risk of radioulnar synostosis.9 Although more frequent in a single-incision approach for distal biceps repair, injury to the posterior interosseous nerve (PIN) is a potentially devastating injury that has been reported with a 2-incision technique.8 The course of the nerve has been described previously,10–21 and prior anatomic studies have shown that the nerve can be moved 1 cm away from the tuberosity with pronation of the forearm.22–26 In the original description of the Boyd-Anderson approach, the arm is flexed and pronated to protect the PIN and fully expose the tuberosity.7 However, the original and subsequent modifications to the 2-incision approach have never made a recommendation as to what degree the elbow should be flexed to safely avoid the PIN. The purpose of the current study was to examine the relationship between the radial tuberosity and the PIN in 90° of flexion vs hyperflexion to establish an optimal position of flexion during the approach. In addition, the authors explored the relationship of the PIN to surgical landmarks used in the modified Boyd-Anderson approach to better evaluate the risk of PIN injury during normal surgical dissection. They also evaluated the proximity of the PIN to radial tuberosity in extension and supination to simulate the approach in a single-incision distal biceps repair. Ten fresh-frozen cadaveric specimens with an intact elbow and forearm were dissected in full pronation using a modified Boyd-Anderson approach as described by Kelly et al.8 The specimens were acquired for research and had not been used for prior dissection. The surgical dissection began with an antecubital incision to identify the distal biceps tendon (Figure 1A). Next, a hemostat clamp was passed through the biceps tunnel around the radius until it was visible subcutaneously. The site where the clamp emerged served as a landmark for the second incision, and a 3-cm incision was made at this point, followed by careful blunt dissection down to the radial tuberosity by splitting the extensor muscles (Figures 1B, C). Figure 1: Photographs showing the antecubital incision with hemostat clamp placed under the distal biceps tendon (A), a 3-cm incision made overlying the dorsal aspect of the forearm to access the radial tuberosity (B), and blunt dissection being used to expose the radial tuberosity (C). After completion of the surgical approach, the dissection was extended to completely visualize the interval between the common extensor tendons and the brachioradialis, with which full exposure of the radial tuberosity and the supinator muscle was established. The supinator was then dissected distally to the point where the PIN exited the supinator muscle (Figure 2). The PIN was tagged with a dyed suture at its exit point from the muscle belly. Figure 2: Photograph showing the exit point of the posterior interosseous nerve from the supinator being used to measure the distance from the posterior interosseous nerve to the radial tuberosity. The length of the radial tuberosity was measured and the midpoint of the tuberosity was marked as a reference. Two methods were used for measuring the distance from the PIN to the radial tuberosity. First, the distance from the tagged portion of the PIN to the marked spot on the radial tuberosity was recorded. Next, a ruler was placed directly on the specimen, and the distance from the PIN to the tuberosity was recorded. These measurements were made in 90° of flexion with full pronation and in hyperflexion with full pronation. In addition, to simulate the location of the PIN during a single-incision biceps repair, the distance of the PIN to the radial tuberosity was recorded in full extension and supination. Results from measurements taken in full flexion and 90° of flexion were assessed for differences using paired t tests conducted with SPSS version 19.0.0 software (SAS Institute, Cary, North Carolina), and differences were deemed significant for P values less than .05. All dissections were performed by the senior author (M.G.G.) and first author (J.A.J.) in a systematic fashion. All measurements were verified by a third resident surgeon (C.M.J.) for accuracy. The PIN was not visualized in any of the surgical approaches; visualization of the PIN was obtained in all specimens after further soft tissue dissection. Mean tuberosity length was 22.7±2.3 mm. Overall, the average distance from the center of the tuberosity to the exit of the PIN from the supinator was 19.9±3.8 mm. In hyperflexion, the average distance was 19.6±4.1 mm (range, 14–25 mm). In 90° of flexion, the average distance was 20.2±3.6 mm (range, 15–26 mm). In extension and full supination, the average distance from the PIN to the tuberosity was 24.8±5.3 mm. Data from these measurements are summarized in Figure 3. The average distance between 90° and hyperflexion was 0.6 mm. Results of a paired t test to assess for differences in a position of flexion yielded a P value of .1656. Figure 3: Graph showing the distance from the posterior interosseous nerve to the radial tuberosity in 90° of flexion vs hyperflexion. Nerve injuries during the 2-incision approach to the distal biceps are common. Kelly et al8 retrospectively reviewed 74 anatomical repairs of the distal biceps tendon using the muscle-splitting Boyd-Anderson approach, with complications developing in 23 (31%) of the 74 repairs. Nerve injuries included 5 sensory nerve paresthesias (3 lateral antebrachial cutaneous and 2 superficial radial nerve paresthesias) in 5 patients. A temporary palsy of the PIN developed in 1 patient (2% of complications), which resolved in 6 months. To the authors’ knowledge, no prior studies have investigated the relationship of the PIN to the radial tuberosity in varying degrees of flexion. The purpose of the current study was to determine whether the degree of elbow flexion affected the position of the PIN in relation to the surgical dissection for the modified Boyd-Anderson approach. In the original and subsequent modifications of this approach, a recommendation was never made as to the optimal degree of elbow flexion to avoid PIN injury. The current authors did not encounter the PIN during the initial surgical dissection in any specimen; after further dissection to locate the nerve, the average distance from the PIN to the radial tuberosity among all specimens was 19.9 mm. Based on these findings and the experience of the senior author, the authors do not believe that the nerve should be commonly visualized during the surgical exposure. In addition, the PIN should not routinely be susceptible to damage from aggressive dissection, although care should be taken to avoid excessive retraction in this region. The position of elbow flexion did not change PIN proximity by more than 2 mm in any specimen, and hyperflexion of the elbow did not universally move the nerve farther away from the tuberosity (specimen 6 moved closer to the nerve in hyperflexion). A paired t test to assess for differences in a position of flexion yielded a P value of .1656, which was not statistically significant. Considering these findings, the authors believe that the degree of flexion is likely a negligible factor in determining the proximity of the nerve to the tuberosity. With the elbow in extension and supination, the PIN was an average distance of 24.8 mm from the radial tuberosity in a distal-radial direction. The authors’ intention was to simulate the relationship of the PIN to the radial tuberosity in the approach for a single-incision distal biceps repair, an approach that has gained recent popularity.5 The advantages and disadvantages of a single-incision approach are beyond the scope of this article, but it is worth mentioning that the current findings are comparable with those of prior studies investigating injury risk to the PIN in single-incision techniques for distal biceps repair. Lo et al27 evaluated the effect of different drill trajectories across the radius on the proximity of the drill tip to the PIN. They recommended drilling across the radius at 90° to its longitudinal axis and aiming from 0° to 30° ulnarly with the patient’s forearm in full supination because this provided an increased margin of safety to prevent injury to the PIN compared with drilling radially with distally.27 The current results support their findings and suggest a safe zone for drilling during a single-incision distal biceps repair because a drill bit exiting the bone more than 1 cm distal-radial to the tuberosity may place the PIN at risk. Several limitations exist for this study. First, fresh-frozen cadavers were used. Although these are routinely considered an acceptable model in anatomic studies, the soft tissues cannot comply in the same way as those of a live patient. Second, despite careful dissection, it is possible the nerve was moved slightly during dissection and exposure. Third, only 10 specimens were used. This study would benefit from a larger number of specimens because the average distance observed between 90° of flexion and hyperflexion was 0.6 mm, and a post-hoc power analysis revealed that 46 specimens would be needed to assess significance at the power level of 90% for this distance. Therefore, anatomic variability may exist in the course of the PIN that was not observed in the 10 specimens, and additional specimens would more reliably show any potential difference between the positions of the arm. However, based on the results of this study, the position of elbow flexion during the surgical approach is likely a negligible factor because the PIN position was unchanged by the degree of elbow flexion. The proximity of the PIN to the radial tuberosity is not significantly affected by the degree of elbow flexion in the muscle-splitting 2-incision approach for distal biceps repair. In addition, the results suggest a safe zone for avoiding PIN injury in a single-incision technique for distal biceps repair because a drill bit exiting the radial tuberosity greater than 1 cm in a distal-radial direction would place the PIN at risk, which is comparable with previous reports.27 Figure 1: Photographs showing the antecubital incision with hemostat clamp placed under the distal biceps tendon (A), a 3-cm incision made overlying the dorsal aspect of the forearm to access the radial tuberosity (B), and blunt dissection being used to expose the radial tuberosity (C). Figure 2: Photograph showing the exit point of the posterior interosseous nerve from the supinator being used to measure the distance from the posterior interosseous nerve to the radial tuberosity. Figure 3: Graph showing the distance from the posterior interosseous nerve to the radial tuberosity in 90° of flexion vs hyperflexion. 10.3928/01477447-20130624-25Keywords
This publication has 23 references indexed in Scilit:
- The Effect of Drill Trajectory on Proximity to the Posterior Interosseous Nerve During Cortical Button Distal Biceps RepairArthroscopy, 2011
- Innervation of the supinator muscle and its relationship to two‐incision distal biceps tendon repair: An anatomic studyClinical Anatomy, 2010
- Anatomical feasibility of transferring supinator motor branches to the posterior interosseous nerve in C7–T1 brachial plexus palsiesJournal of Neurosurgery, 2009
- Repair of the Ruptured Distal Biceps TendonThe American Journal of Sports Medicine, 2008
- Superficial surgical landmarks for identifying the posterior interosseous nerveJournal of Neurosurgery, 2006
- Anatomic pattern of the terminal branches of posterior interosseous nerveClinical Anatomy, 2005
- Distal Biceps Tendon RupturesClinical Orthopaedics and Related Research, 2002
- Anatomic study of posterior interosseous nerve in the arcade of FrohseJournal of Shoulder and Elbow Surgery, 1999
- Anatomy of the radial nerve motor branches in the forearmThe Journal of Hand Surgery, 1997
- A study of the posterior interosseous nerve (PIN) and the radial tunnel in 30 Thai cadaversThe Journal of Hand Surgery, 1993