TG‐69: Radiographic film for megavoltage beam dosimetry
Authors:
- Indra J. DasIDIndra J. Das
- James F. DempseyJDJames F. Dempsey
- Kwok L. LamKLKwok L. Lam
- Thomas J. LoSassoTLThomas J. LoSasso
- Arthur J. OlchAOArthur J. Olch
- Jatinder R. PaltaJPJatinder R. Palta
- Lawrence E. ReinsteinLRLawrence E. Reinstein
- Dan RittDRDan Ritt
- Ellen E. WilcoxEWEllen E. Wilcox
Open Access
- 25 May 2007
- journal article
- Published by Wiley in Medical Physics
- Vol. 34 (6Part1) , 2228-2258
Abstract
TG‐69 is a task group report of the AAPM on the use of radiographic film for dosimetry. Radiographic films have been used for radiation dosimetry since the discovery of x‐rays and have become an integral part of dose verification for both routine quality assurance and for complex treatments such as soft wedges (dynamic and virtual), intensity modulated radiation therapy (IMRT), image guided radiation therapy (IGRT), and small field dosimetry like stereotactic radiosurgery. Film is convenient to use, spatially accurate, and provides a permanent record of the integrated two dimensional dose distributions. However, there are several challenges to obtaining high quality dosimetric results with film, namely, the dependence of optical density on photon energy, field size, depth, film batch sensitivity differences, film orientation, processing conditions, and scanner performance. Prior to the clinical implementation of a film dosimetry program, the film, processor, and scanner need to be tested to characterize them with respect to these variables. Also, the physicist must understand the basic characteristics of all components of film dosimetry systems. The primary mission of this task group report is to provide guidelines for film selection, irradiation, processing, scanning, and interpretation to allow the physicist to accurately and precisely measure dose with film. Additionally, we present the basic principles and characteristics of film, processors, and scanners. Procedural recommendations are made for each of the steps required for film dosimetry and guidance is given regarding expected levels of accuracy. Finally, some clinical applications of film dosimetry are discussed.Keywords
This publication has 96 references indexed in Scilit:
- Evaluation of a 2D diode array for IMRT quality assuranceRadiotherapy and Oncology, 2004
- Dosimetric properties of an amorphous silicon electronic portal imaging device for verification of dynamic intensity modulated radiation therapyMedical Physics, 2003
- Dosimetric comparison of extended dose range film with ionization measurements in water and lung equivalent heterogeneous media exposed to megavoltage photonsJournal of Applied Clinical Medical Physics, 2003
- Film dosimetry for intensity modulated radiation therapy: Dosimetric evaluationMedical Physics, 2002
- Physical and dosimetric aspects of a multileaf collimation system used in the dynamic mode for implementing intensity modulated radiotherapyMedical Physics, 1998
- A filtration method for improving film dosimetry in photon radiation therapyMedical Physics, 1997
- Quantitative evaluation of radiochromic film response for two‐dimensional dosimetryMedical Physics, 1997
- Testing of dynamic multileaf collimationMedical Physics, 1996
- Evaluation of a diode detector array for measurement of dynamic wedge dose distributionsMedical Physics, 1993
- Effective wedge angles with a universal wedgePhysics in Medicine & Biology, 1985