Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants.
Authors:
- D SchranzDSD Schranz
- R HuthRHR Huth
- F ZeppFZF Zepp
- H OelertHOH Oelert
- B K JungstBJB K Jungst
Abstract
OBJECTIVE--To compare cardiac output measurements in critically ill infants by the dual beam Doppler and thermodilution techniques. DESIGN--Prospective direct comparison of the two techniques. For statistical evaluation one randomly assigned paired measurement of every patient was used. SETTING--Paediatric intensive care unit in a university hospital. PATIENTS--18 infants after open heart surgery aged 4-25 months (weight 4-10 kg). INTERVENTIONS--Cardiac output measurements by dual beam Doppler and thermodilution techniques were performed within 10 minutes of each other and without knowledge of the results of the other methods. Multiple measurements were performed on some patients with a pharmacological or electrophysiological intervention or with a minimum of six hours between each pair of measurements. MEASUREMENTS AND MAIN RESULTS--Three patients were excluded because of an inadequate Doppler signal or a significant residual shunt. Cardiac output measurements ranged from 0.4 to 2.2 l/min for the thermodilution technique and from 0.5 to 2.1 l/min for the dual beam Doppler technique. Agreement between both methods was acceptable. The mean difference between the two methods was 0.026 l/min with two standard deviations ranging from -0.20 to 0.26 l/min. CONCLUSION--The dual beam Doppler technique was shown to have promise for the non-invasive determination of cardiac output in critically ill infants.Keywords
This publication has 21 references indexed in Scilit:
- Automated non-invasive measurement of cardiac output by the carbon dioxide rebreathing method: comparisons with dye dilution and thermodilution.Heart, 1990
- A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill childrenThe Journal of Pediatrics, 1989
- How much does aortic and pulmonary artery area vary during the cardiac cycle?American Heart Journal, 1987
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Doppler echocardiographic measurement of cardiac output: Comparison with a non-golden standardThe American Journal of Cardiology, 1984
- Noninvasive Doppler determination of cardiac output in man. Clinical validation.Circulation, 1983
- Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast fourier transform spectral analysisThe American Journal of Cardiology, 1982
- Noninvasive pulsed Doppler determination of cardiac output in neonates and childrenThe Journal of Pediatrics, 1982
- Overestimation of pediatric cardiac output by thermal indicator loss.Circulation, 1982
- Bedside pulmonary artery catheterzation in pediatricsThe Journal of Pediatrics, 1980