Application of singularity expansion method for monitoring the deployment of arterial stents
- 18 July 2012
- journal article
- research article
- Published by Wiley in Microwave and Optical Technology Letters
- Vol. 54 (10) , 2241-2246
Abstract
A stent is a metal tube used to treat blocked blood vessels in the body. The stent is deployed into obstructed part of the blood vessel to keep it open and improve the blood flow in the diseased area. During the stent implantation, the collapsed stent is expanded into the artery to a size so as to stick to the artery walls. Because of the significant health dangers caused by the over‐expansion or under‐expansion of the stent, having a proper estimation of diameter of the stent in the artery during expansion is important. However, yet to date, no method exists that would allow real time monitoring during and after the stent expansion process. In this article, we present a novel methodology to estimate diameter of the stent during and after deployment in the artery by applying the singularity expansion method (SEM). According to SEM, the transient electromagnetic signal scattered from bodies can be described by poles and residues. Poles are intrinsic property of the body that can be used to detect deformation of an object such as expansion. We have demonstrated the idea of estimating diameter of a stent via tracking poles by both simulation and measurement. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:2241–2246, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27053Keywords
Funding Information
- Institute for Critical Technology and Applied Science, ICTAS, at Virginia Tech
This publication has 16 references indexed in Scilit:
- A novel approach to improve noise reduction in the Matrix Pencil Algorithm for chipless RFID tag detection2010
- Stent Overexpansion and Myocardial No-ReflowJACC, 2009
- Coronary-Artery Stents — Gauging, Gorging, and GougingNew England Journal of Medicine, 1998
- Recommendations on stent manufacture, implantation and utilizationEuropean Heart Journal, 1997
- The history of interventional cardiology: Cardiac catheterization, angioplasty, and related interventionsAmerican Heart Journal, 1995
- The singularity expansion method and its application to target identificationProceedings of the IEEE, 1991
- Matrix pencil method for estimating parameters of exponentially damped/undamped sinusoids in noiseIEEE Transactions on Acoustics, Speech, and Signal Processing, 1990
- Identification of rational transfer function from frequency response sampleIEEE Transactions on Aerospace and Electronic Systems, 1990
- A wavefront interpretation of the singularity expansion methodIEEE Transactions on Antennas and Propagation, 1985
- Complex-curve fittingIRE Transactions on Automatic Control, 1959