LC-MS/MS method for hepcidin-25 measurement in human and mouse serum: clinical and research implications in iron disorders
- 1 January 2015
- journal article
- research article
- Published by Walter de Gruyter GmbH in Clinical Chemistry and Laboratory Medicine (CCLM)
- Vol. 53 (10) , 1557-1567
Abstract
Background: The peptide hepcidin plays a central role in regulating dietary iron absorption and body iron distribution. This 25-amino acid hormone is produced and secreted predominantly by hepatocytes. Hepcidin has been suggested as a promising diagnostic marker for iron-related disorders. However, its accurate quantification for clinical use remains so far challenging. In this report we describe a highly specific and quantitative serum hepcidin method using liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Material: The analytical validation included the determination of the limit of detection, of quantification, repeatability, reproducibility and linearity. This assay was developed for human and mouse hepcidin. The human assay was performed on serum patients with unexplained microcytic anemia. We applied our LC-MS/MS method for quantifying hepcidin-1 in mouse in various conditions: inflammation, hemolytic anemia, Hamp-1, Hjv and Hfe KO mice. Results: We show that the LC-MS/MS is suitable for accurate determination of hepcidin-25 in clinical samples, thereby representing a useful tool for the clinical diagnosis and follow-up of iron-related diseases. In mouse, a strong correlation between hepatic Hamp-1 mRNA expression and serum hepcidin-1 levels was found (r = 0.88; p = 0.0002) and the expected variations in mouse models of iron disorders were observed. Conclusions: Therefore, we propose this adaptive LC-MS/MS method as a suitable method for accurate determination of hepcidin-25 in clinical samples and as a major tool contributing to the clinical diagnosis, follow-up and management of iron-related disorders. It also opens new avenues to measure hepcidin in animal models without interspecies antigenic limitations.Keywords
This publication has 16 references indexed in Scilit:
- Out of Balance—Systemic Iron Homeostasis in Iron-Related DisordersNutrients, 2013
- Iron refractory iron deficiency anemiaHaematologica, 2013
- Inactive matriptase-2 mutants found in IRIDA patients still repress hepcidin in a transfection assay despite having lost their serine protease activityHuman Mutation, 2012
- Development of a nano-liquid chromatography on chip tandem mass spectrometry method for high-sensitivity hepcidin quantitationJournal of Chromatography A, 2011
- Design and Validation of a High-Throughput Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Method for Quantification of Hepcidin in Human PlasmaAnalytical Chemistry, 2011
- Hepcidin is localised in gastric parietal cells, regulates acid secretion and is induced by Helicobacter pylori infectionGut, 2011
- Mass Spectrometry Analysis of Hepcidin Peptides in Experimental Mouse ModelsPLOS ONE, 2011
- Iron Sequestration and Anemia of InflammationSeminars in Hematology, 2009
- Phlebotomies or erythropoietin injections allow mobilization of iron stores in a mouse model mimicking intensive care anemiaCritical Care Medicine, 2008
- Targeted disruption of the hepcidin 1 gene results in severe hemochromatosisBlood, 2006