High-resolution high-sensitivity elemental imaging by secondary ion mass spectrometry: from traditional 2D and 3D imaging to correlative microscopy
- 5 October 2015
- journal article
- Published by IOP Publishing in Nanotechnology
- Vol. 26 (43) , 434001
Abstract
Secondary ion mass spectrometry (SIMS) constitutes an extremely sensitive technique for imaging surfaces in 2D and 3D. Apart from its excellent sensitivity and high lateral resolution (50 nm on state-of-the-art SIMS instruments), advantages of SIMS include high dynamic range and the ability to differentiate between isotopes. This paper first reviews the underlying principles of SIMS as well as the performance and applications of 2D and 3D SIMS elemental imaging. The prospects for further improving the capabilities of SIMS imaging are discussed. The lateral resolution in SIMS imaging when using the microprobe mode is limited by (i) the ion probe size, which is dependent on the brightness of the primary ion source, the quality of the optics of the primary ion column and the electric fields in the near sample region used to extract secondary ions; (ii) the sensitivity of the analysis as a reasonable secondary ion signal, which must be detected from very tiny voxel sizes and thus from a very limited number of sputtered atoms; and (iii) the physical dimensions of the collision cascade determining the origin of the sputtered ions with respect to the impact site of the incident primary ion probe. One interesting prospect is the use of SIMS-based correlative microscopy. In this approach SIMS is combined with various high-resolution microscopy techniques, so that elemental/chemical information at the highest sensitivity can be obtained with SIMS, while excellent spatial resolution is provided by overlaying the SIMS images with high-resolution images obtained by these microscopy techniques. Examples of this approach are given by presenting in situ combinations of SIMS with transmission electron microscopy (TEM), helium ion microscopy (HIM) and scanning probe microscopy (SPM).Keywords
Funding Information
- Fonds National de la Recherche Luxembourg (He-SIMS (C10/MS/801311), LowZ-PIES (C13/MS/5951975), PIES (C09/MS/13), SIMS-SPM (FNR-MAT-08-01))
- Intelligence Advanced Research Projects Activity (FA8650-11-C-7100)
This publication has 140 references indexed in Scilit:
- Multi-isotope imaging mass spectrometry reveals slow protein turnover in hair-cell stereociliaNature, 2012
- Correlative 3D imaging of whole mammalian cells with light and electron microscopyJournal of Structural Biology, 2011
- The power of correlative microscopy: multi-modal, multi-scale, multi-dimensionalCurrent Opinion in Structural Biology, 2011
- Whole-Cell Imaging at Nanometer Resolutions Using Fast and Slow Focused Helium IonsBiophysical Journal, 2011
- SIMS analysis of an UO2 fuel irradiated at low temperature to 65MWd/kgHMJournal of Nuclear Materials, 2009
- The Hyperion™ Ion Probe for Next Generation FIB, SIMS and Nano-Ion, ImplantationMicroscopy and Microanalysis, 2009
- SIMS characterisation of actinide isotopes in irradiated nuclear fuelJournal of Nuclear Materials, 2009
- High-resolution imaging of complex crack chemistry in reactor steels by NanoSIMSJournal of Nuclear Materials, 2008
- An Introduction to Helium Ion MicroscopyMicroscopy and Microanalysis, 2006
- Tridyn-binary collision simulation of atomic collisions and dynamic composition changes in solidsComputer Physics Communications, 1988