Exergy Analysis of Adiabatic Liquid Air Energy Storage (A-LAES) System Based on Linde–Hampson Cycle
Open Access
Abstract
Efficiently storing energy on a large scale poses a major challenge and one that is growing in importance with the increasing share of renewables in the energy mix. The only options at present are either pumped hydro or compressed air storage. One novel alternative is to store energy using liquid air, but this technology is not yet fully mature and requires substantial research and development, including in-depth energy and exergy analysis. This paper presents an exergy analysis of the Adiabatic Liquid Air Energy Storage (A-LAES) system based on the Linde–Hampson cycle. The exergy analysis was carried out for four cases with different parameters, in particular the discharge pressure of the air at the inlet of the turbine (20, 40, 100, 150 bar). The results of the analysis show that the greatest exergy destruction can be observed in the air evaporator and in the Joule–Thompson valve. In the case of air evaporator, the destruction of exergy is greatest for the lowest discharge pressure, i.e., 20 bar, and reaches over 118 MWh/cycle. It decreases with increasing discharge pressure, down to approximately 24 MWh/cycle for 150 bar, which is caused by a decrease in the heat of vaporization of air. In the case of Joule–Thompson valve, the changes are reversed. The highest destruction of exergy is observed for the highest considered discharge pressure (150 bar) and amounts to over 183 MWh/cycle. It decreases as pressure is lowered to 57.5 MWh/cycle for 20 bar. The other components of the system do not show exergy destruction greater than approximately 50 MWh/cycle for all considered pressures. Specific liquefaction work of the system ranged from 0.189 kWh/kgLA to 0.295 kWh/kgLA and the efficiency from 44.61% to 55.18%.Keywords
Funding Information
- Scientific Council of the Discipline of Environmental Engineering, Mining and Power Engineering and the Dean of the Faculty of Power and Aeronautical Engineering of the Warsaw University of Technology (Internal Grant for employees of the Warsaw University of Technology in 2020)
This publication has 33 references indexed in Scilit:
- Thermodynamic and exergy analysis of a combined pumped hydro and compressed air energy storage systemSustainable Cities and Society, 2019
- Energy security and energy storage technologiesEnergy Procedia, 2018
- The development of techno-economic models for large-scale energy storage systemsEnergy, 2017
- Performance Analysis and Detailed Experimental Results of the First Liquid Air Energy Storage Plant in the WorldJournal of Energy Resources Technology, 2017
- Liquid air energy storage – Analysis and first results from a pilot scale demonstration plantApplied Energy, 2015
- Multi criteria site selection model for wind-compressed air energy storage power plants in IranRenewable and Sustainable Energy Reviews, 2014
- Overview of Current Development in Compressed Air Energy Storage TechnologyEnergy Procedia, 2014
- The operational economics of compressed air energy storage systems under uncertaintyRenewable and Sustainable Energy Reviews, 2013
- Baseload electricity from wind via compressed air energy storage (CAES)Renewable and Sustainable Energy Reviews, 2012
- Optimal operation strategies of compressed air energy storage (CAES) on electricity spot markets with fluctuating pricesApplied Thermal Engineering, 2009