Mechanical stresses associated with flattening of human femoropopliteal artery specimens during planar biaxial testing and their effects on the calculated physiologic stress–stretch state
- 8 May 2019
- journal article
- research article
- Published by Springer Nature in Biomechanics and Modeling in Mechanobiology
- Vol. 18 (6) , 1591-1605
Abstract
Planar biaxial testing is commonly used to characterize the mechanical properties of arteries, but stresses associated with specimen flattening during this test are unknown. We quantified flattening effects in human femoropopliteal arteries (FPAs) of different ages and determined how they affect the calculated arterial physiologic stress–stretch state. Human FPAs from 472 tissue donors (age 12–82 years, mean 53 ± 16 years) were tested using planar biaxial extension, and morphometric and mechanical characteristics were used to assess the flattening effects. Constitutive parameters for the invariant-based model were adjusted to account for specimen flattening and used to calculate the physiologic stresses, stretches, axial force, circumferential stiffness, and stored energy for the FPAs in seven age groups. Flattened specimens were overall 12 ± 4% stiffer longitudinally and 19 ± 11% stiffer circumferentially when biaxially tested. Differences between the stress–stretch curves adjusted and non-adjusted for the effects of flattening were relatively constant across all age groups longitudinally, but increased with age circumferentially. In all age groups, these differences were smaller than the intersubject variability. Physiologic stresses, stretches, axial force, circumferential stiffness, and stored energy were all qualitatively and quantitatively similar when calculated with and without the flattening effects. Stresses, stretches, axial force, and stored energy reduced with age, but circumferential stiffness remained relatively constant between 25 and 65 years of age suggesting a homeostatic target of 0.75 ± 0.02 MPa. Flattening effects associated with planar biaxial testing are smaller than the intersubject variability and have little influence on the calculated physiologic stress–stretch state of human FPAs.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (R01 HL125736)
This publication has 40 references indexed in Scilit:
- 3D constitutive modeling of the biaxial mechanical response of intact and layer-dissected human carotid arteriesJournal of the Mechanical Behavior of Biomedical Materials, 2012
- A Multi-Layered Computational Model of Coupled Elastin Degradation, Vasoactive Dysfunction, and Collagenous Stiffening in Aortic AgingAnnals of Biomedical Engineering, 2011
- Methods to compute 3D residual stress distributions in hyperelastic tubes with application to arterial wallsInternational Journal of Engineering Science, 2010
- On constitutive descriptors of the biaxial mechanical behaviour of human abdominal aorta and aneurysmsJournal of The Royal Society Interface, 2010
- Modelling the layer-specific three-dimensional residual stresses in arteries, with an application to the human aortaJournal of The Royal Society Interface, 2009
- Origin of axial prestretch and residual stress in arteriesBiomechanics and Modeling in Mechanobiology, 2009
- One-Year Costs in Patients With a History of or at Risk for Atherothrombosis in the United StatesCirculation: Cardiovascular Quality and Outcomes, 2008
- Growth and remodeling in a thick-walled artery model: effects of spatial variations in wall constituentsBiomechanics and Modeling in Mechanobiology, 2007
- Aorta in vivo parameter identification using an axial force constraintBiomechanics and Modeling in Mechanobiology, 2005
- Analysis of the passive mechanical properties of rat carotid arteriesJournal of Biomechanics, 1983