Effects of laser repetition rate on corneal tissue ablation for 193‐nm excimer laser light
Authors:
- 25 August 2008
- journal article
- research article
- Published by Wiley in Lasers in Surgery and Medicine
- Vol. 40 (7) , 483-493
Abstract
Background and Objective The goal of the present work is to assess whether bovine corneal ablations generated at laser repetition rates of up to 400 Hz are comparable to ablations performed at rates consistent with current clinical laser systems. Study Design/Materials and Methods A combination of experiments was used to assess a comprehensive range of ablation parameters, including ablation plume dynamics via imaging and transmission, corneal ablation profiles via scanning interferometry, and high-resolution electron microscopy of collagen structure following ablation. Results Using white-light interferometry analysis, no statistical difference was found between corneal ablation profiles created at 60 and 400 Hz, with an average rate of 0.94 µm/pulse at 60 Hz versus 0.92 µm/pulse at 400 Hz. In addition, based on plume imaging and transmission studies, the bulk ablation plume was found to dissipate on a time-scale less than the pulse-to-pulse separation for a laser repetition rate up to about 400 Hz. A persistent, diffuse gas-phase component of the ablation products was observed and concluded to be comparable at both repetition rates. Finally, SEM and TEM analysis revealed no signs of differential thermal tissue damage, including collagen fibril analysis, for laser repetition rates up to 400 Hz. Conclusions In summary, investigation of the relative effects of excimer laser repetition rate on the overall corneal ablation metrics revealed no measurable difference under conditions typical of clinical refractive procedures. This study suggests that increases in ArF laser repetition rates for clinical applications (up to ∼400 Hz) appear feasible. Lesers Surg. Med. 40:483–493, 2008.Keywords
This publication has 35 references indexed in Scilit:
- Mechanisms of Pulsed Laser Ablation of Biological TissuesChemical Reviews, 2003
- Plume dynamics and shielding by the ablation plume during Er:YAG laser ablationJournal of Biomedical Optics, 2002
- Mechanism study of porcine skin ablation by nanosecond laser pulses at 1064, 532, 266, and 213 nmIEEE Journal of Quantum Electronics, 2001
- Laser-induced photodecomposition of amino acids and peptides: extrapolation to corneal collagenIEEE Journal of Selected Topics in Quantum Electronics, 1999
- The Effect of Laser Parameters on the Zone of Thermal Injury Produced by Laser Ablation of Biological TissueJournal of Biomechanical Engineering, 1994
- Model simulation of biological damage in tissue exposed to CO[sup 2] laser irradiationOptical Engineering, 1993
- The physics of UV laser cornea ablationIEEE Journal of Quantum Electronics, 1991
- The effect of CO/sub 2/ laser pulse repetition rate on tissue ablation rate and thermal damageIEEE Transactions on Biomedical Engineering, 1991
- Quantitative and ultrastructural studies of excimer laser ablation of the cornea at 193 and 248 nanometersLasers in Surgery and Medicine, 1987
- Photochemical cleavage of a polymeric solid: details of the ultraviolet laser ablation of poly(methyl methacrylate) at 193 nm and 248 nmMacromolecules, 1986