Millimeter-Wave Imaging Using Reverse-Microscope and Scanning System
- 1 December 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 161-163
Abstract
In this paper, firstly, focal field of Reverse-Microscope System (RMS) at millimeter wavelengths is analyzed, The contour diagram of electric field in the focal plane of RMS when the linearly polarized plane wave impact on it with different incident angles is calculated with ray-tracing method and Stratton-Chu vector diffraction integral formula. Then we add a scanning system in front of the RMS to form a Scanning Reverse-Microscope System (SRMS). The contour diagram of the SRMS is also calculated. The numerical results are very useful for us to design a millimeter-wave imaging system with low cost and high performance in our next work.Keywords
This publication has 4 references indexed in Scilit:
- Stand-off detection of hidden threat objects on personnel at checkpoints and in public areas using active millimetre-wave imaging2004
- ANALYSIS OF EXTENDING THE FIELD-OF-VIEW OF REVERSE-MICROSCOPE IMAGING SYSTEM AT MILLIMETER-WAVELENGTHSJournal of Electromagnetic Waves and Applications, 2004
- Optimal dithering of focal plane arrays in passive millimeter-wave imagingOptical Engineering, 2001
- Passive millimeter-wave imaging for contraband detection1998