The potential failure risk of the cone-beam computed tomography-based planning target volume margin definition for prostate image-guided radiotherapy based on a prospective single-institutional hybrid analysis
Authors:
- Katsumi HiroseKHKatsumi Hirose
- Mariko SatoMSMariko Sato
- Yoshiomi HatayamaYHYoshiomi Hatayama
- Hideo KawaguchiHKHideo Kawaguchi
- Fumio KomaiFKFumio Komai
- Makoto SohmaMSMakoto Sohma
- Hideki ObaraHOHideki Obara
- Masashi SuzukiMSMasashi Suzuki
- Mitsuki TanakaMTMitsuki Tanaka
- Ichitaro FujiokaIFIchitaro Fujioka
- Koji IchiseKIKoji Ichise
- Yoshihiro TakaiYTYoshihiro Takai
Open Access
- 7 June 2018
- journal article
- research article
- Published by Springer Nature in Radiation Oncology
- Vol. 13 (1) , 106
Abstract
The purpose of this study was to evaluate the impact of markerless on-board kilovoltage (kV) cone-beam computed tomography (CBCT)-based positioning uncertainty on determination of the planning target volume (PTV) margin by comparison with kV on-board imaging (OBI) with gold fiducial markers (FMs), and to validate a methodology for the evaluation of PTV margins for markerless kV-CBCT in prostate image-guided radiotherapy (IGRT). A total of 1177 pre- and 1177 post-treatment kV-OBI and 1177 pre- and 206 post-treatment kV-CBCT images were analyzed in 25 patients who received prostate IGRT with daily localization by implanted FMs. Intrafractional motion of the prostate was evaluated between each pre- and post-treatment image with these two different techniques. The differences in prostate deviations and intrafractional motions between matching by FM in kV-OBI (OBI-FM) and matching by soft tissues in kV-CBCT (CBCT-ST) were compared by Bland-Altman limits of agreement. Compensated PTV margins were determined and compensated by references. Mean differences between OBI-FM and CBCT-ST in the anterior to posterior (AP), superior to inferior (SI), and left to right (LR) directions were − 0.43 ± 1.45, − 0.09 ± 1.65, and − 0.12 ± 0.80 mm, respectively, with R2 = 0.85, 0.88, and 0.83, respectively. Intrafractional motions obtained from CBCT-ST were 0.00 ± 1.46, 0.02 ± 1.49, and 0.15 ± 0.64 mm, respectively, which were smaller than the results from OBI-FM, with 0.43 ± 1.90, 0.12 ± 1.98, and 0.26 ± 0.80 mm, respectively, with R2 = 0.42, 0.33, and 0.16, respectively. Bland-Altman analysis showed a significant proportional bias. PTV margins of 1.5 mm, 1.4 mm, and 0.9 mm for CBCT-ST were calculated from the values of CBCT-ST, which were also smaller than the values of 3.15 mm, 3.66 mm, and 1.60 mm from OBI-FM. The practical PTV margin for CBCT-ST was compensated with the values from OBI-FM as 4.1 mm, 4.8 mm, and 2.2 mm. PTV margins calculated from CBCT-ST might be underestimated compared to the true PTV margins. To determine a reliable CBCT-ST-based PTV margin, at least the systemic error Σ and the random error σ for on-line matching errors need to be investigated by supportive preliminary FM evaluation at least once.Keywords
This publication has 39 references indexed in Scilit:
- Comparison of high‐dose (86.4 G y) IMRT vs combined brachytherapy plus IMRT for intermediate‐risk prostate cancerBJU International, 2014
- Interfraction rotation of the prostate as evaluated by kilovoltage X-ray fiducial marker imaging in intensity-modulated radiotherapy of localized prostate cancerMedical Dosimetry, 2012
- Image-guided radiotherapy using surgical clips as fiducial markers after prostatectomy: A report of total setup error, required PTV expansion, and dosimetric implicationsRadiotherapy and Oncology, 2012
- A Comparison of In-Room Computerized Tomography Options for Detection of Fiducial Markers in Prostate Cancer RadiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- Ultra-High Dose (86.4 Gy) IMRT for Localized Prostate Cancer: Toxicity and Biochemical OutcomesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Prostate position relative to pelvic bony anatomy based on intraprostatic gold markers and electronic portal imagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Phase III pilot study of dose escalation using conformal radiotherapy in prostate cancer: PSA control and side effectsBritish Journal of Cancer, 2005
- Impact of volume and location of irradiated rectum wall on rectal blood loss after radiotherapy of prostate cancerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2004
- Clinical experience with intensity modulated radiation therapy (IMRT) in prostate cancerRadiotherapy and Oncology, 2000
- Comparison of radiation side-effects of conformal and conventional radiotherapy in prostate cancer: a randomised trialThe Lancet, 1999