Does the Use of Intraoperative Neuromonitoring during Thyroid and Parathyroid Surgery Reduce the Incidence of Recurrent Laryngeal Nerve Injuries? A Systematic Review and Meta-Analysis
Open Access
- 23 April 2024
- journal article
- review article
- Published by MDPI AG in Diagnostics
- Vol. 14 (9) , 860
Abstract
Injury to the recurrent laryngeal nerve (RLN) can be a devastating complication of thyroid and parathyroid surgery. Intraoperative neuromonitoring (IONM) has been proposed as a method to reduce the number of RLN injuries but the data are inconsistent. We performed a meta-analysis to critically assess the data. After applying inclusion and exclusion criteria, 60 studies, including five randomized trials and eight non-randomized prospective trials, were included. A meta-analysis of all studies demonstrated an odds ratio (OR) of 0.66 (95% CI [0.56, 0.79], p < 0.00001) favoring IONM compared to the visual identification of the RLN in limiting permanent RLN injuries. A meta-analysis of studies employing contemporaneous controls and routine postoperative laryngoscopy to diagnose RLN injuries (considered to be the most reliable design) demonstrated an OR of 0.69 (95% CI [0.56, 0.84], p = 0.0003), favoring IONM. Strong consideration should be given to employing IONM when performing thyroid and parathyroid surgery.Keywords
This publication has 87 references indexed in Scilit:
- The utility of intraoperative nerve monitoring in secondary and tertiary Hyperparathyroid surgeryClinical Case Reports, 2021
- Methodological Quality of Systematic Reviews of Intraoperative Neuromonitoring in ThyroidectomyJAMA Otolaryngology–Head & Neck Surgery, 2019
- Intraoperative neuromonitoring versus visual nerve identification for prevention of recurrent laryngeal nerve injury in adults undergoing thyroid surgeryCochrane Database of Systematic Reviews, 2019
- Association of Intraoperative Neuromonitoring With Reduced Recurrent Laryngeal Nerve Injury in Patients Undergoing Total ThyroidectomyJAMA Otolaryngology–Head & Neck Surgery, 2016
- Intermittent intraoperative nerve monitoring in thyroid reoperations: Preliminary results of a randomized, single-surgeon studyHead & Neck, 2016
- Randomized clinical trial of visualization versus neuromonitoring of recurrent laryngeal nerves during thyroidectomyBritish Journal of Surgery, 2009
- Laryngeal Nerve Monitoring and Minimally Invasive Thyroid SurgeryJAMA Otolaryngology–Head & Neck Surgery, 2007
- Incidence of Vocal Cord Paralysis With and Without Recurrent Laryngeal Nerve Monitoring During ThyroidectomyJAMA Otolaryngology–Head & Neck Surgery, 2007
- Suspensory ligament of Berry: Its relationship to recurrent laryngeal nerve and anatomic examination of 24 autopsiesHead & Neck, 1998
- Practical Anatomical Considerations in Thyroid Tumor SurgeryJAMA Otolaryngology–Head & Neck Surgery, 1983