Evaluation of a Novel System for RFID Intraoperative Cardiovascular Analytics
Open Access
- 5 August 2022
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 10, 1-9
Abstract
Objective: To evaluate a novel technology for real time tracking of RF-Identified (RFID) surgical tools (Biotic System), providing intraoperative data analytics during simulated cardiovascular procedures. Ineffective asset management in the Operating Room (OR) leads to inefficient utilization of resources and contributes to prolonged operative times and increased costs. Analysis of captured data can assist in quantifying instrument utilization, procedure flow, performance and prevention of retained instruments. Methods & Results: Five surgeons performed thirteen simulated surgical cases on three human cadavers. Procedures included (i) two abdominal aortic aneurysm (AAA) repairs, (ii) three carotid endarterectomies (CE), (iii) two femoropopliteal (fem-pop) bypasses, (iv) thoracic aortic aneurysm repair, (v) coronary artery bypass graft, (vi) aortic valve replacement, (vii) ascending aortic aneurysm repair, (viii) heart transplants, and (ix) mitral valve replacement. For each case an average of 139 surgical instruments were RFID-tagged and tracked intraoperatively. Data was captured and analyzed retrospectively. Of the 139 instruments tracked across each of the 13 cases, 55 instruments (39.5%) were actually used, demonstrating a high level of redundancy. For repeat cases (i.e. CE/AAA/fem-pop): (i) average instrument usage was 41 ± 3.6 (8.8% variation) for CE (n=3); (ii) average instrument usage was 69 ± 4.0 (5.8% variation) for AAA (n=2); and (iii) average instrument usage was 48 ± 2.5 (5.3% variation) for fem- pop (n=2). Results also showed a reduction in end-of-procedure instrument counting times of 58-87%. Conclusions: We report on a method for collecting intraoperative data analytics regarding instrument usage via RFID technology. This system will help refine instrument selection, quantitate instrument utilization and prevent inadvertent retention in a patient. This should help increase efficiency in packaging and sterilization and let surgeons make objective decisions in the composition of surgical trays. Clinical and Translational Impact Statement —Intraoperative analytics of surgical tools and associated equipment may ultimately lead to safer more efficient surgeries that increase patient outcomes while decreasing the cost of care.Keywords
Funding Information
- National Center for Advancing Translational Sciences, National Institutes of Health (1R41TR003249-01)
This publication has 14 references indexed in Scilit:
- Reduction of Proximity Effects on UHF Passive RFID Systems by Using Tags With Polarization DiversityIEEE Transactions on Antennas and Propagation, 2015
- Assessing the Magnitude and Costs of Intraoperative Inefficiencies Attributable to Surgical Instrument TraysJournal of the American College of Surgeons, 2014
- Power margin reduction in linear passive UHF RFID tag arrays2014
- The Impact of Operative Time on Complications After Plastic Surgery: A Multivariate Regression Analysis of 1753 CasesAesthetic Surgery Journal, 2014
- Epidemiology and outcomes of surgical site infections following orthopedic surgeryAmerican Journal of Infection Control, 2013
- Sensitivity of detection of radiofrequency surgical sponges: a prospective, cross-over studyThe American Journal of Surgery, 2011
- Factors affecting the incidence of infection in hip and knee replacementThe Journal of Bone and Joint Surgery. British volume, 2010
- Cardiac surgical theatre traffic: time for traffic calming measures?Interactive CardioVascular and Thoracic Surgery, 2010
- A prospective study of patient safety in the operating roomSurgery, 2006
- Communication failures in the operating room: an observational classification of recurrent types and effectsQuality and Safety in Health Care, 2004