Unique Nonenzymatic Glucose Sensor Using a Hollow-Shelled Triple Oxide Mn–Cu–Al Nanocomposite
- 12 September 2020
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 5 (37) , 23502-23509
Abstract
Glucose monitoring devices for diabetes mellitus, which is a worldwide significant health issue, have attracted attention of many researchers. Herein, we report a hollow Mn–Cu–Al oxide nanocomposite (HMCA) by a microwave-assisted technique showing excellent sensing abilities toward glucose. Also, it possesses a superb supercapacitor activity described in our previous paper. The sensitivity value of the nanocomposite is 2.194 mA mM–1 cm–2 with a low detection limit of 0.43 μM (S/N = 3). The high sensitivity and low detection limit were the results of the large surface area of the nanocomposite and the redox nature of CuO and MnO2. It shows a selective detection of glucose levels in blood serum. The hollow nanocomposite has been useful for monitoring the glucose level in blood serum and holds great potential for diabetes mellitus and clinical diagnosis.Keywords
Funding Information
- Ministry of Education, India
- National Institute of Technology Tiruchirappalli
This publication has 44 references indexed in Scilit:
- Rational design of binder-free noble metal/metal oxide arrays with nanocauliflower structure for wide linear range nonenzymatic glucose detectionScientific Reports, 2015
- A Review of Glucose Biosensors Based on Graphene/Metal Oxide NanomaterialsAnalytical Letters, 2014
- Performance studies of Pd–Pt and Pt–Pd–Au catalyst for electro-oxidation of glucose in direct glucose fuel cellInternational Journal of Hydrogen Energy, 2012
- Nonenzymatic glucose sensor based on ultrasonic-electrodeposition of bimetallic PtM (M = Ru, Pd and Au) nanoparticles on carbon nanotubes–ionic liquid composite filmBiosensors and Bioelectronics, 2009
- Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrodeBiosensors and Bioelectronics, 2009
- Direct Electrochemistry of Glucose Oxidase and Biosensing for Glucose Based on GrapheneAnalytical Chemistry, 2009
- An improved sensitivity non-enzymatic glucose sensor based on a CuO nanowire modified Cu electrodeThe Analyst, 2007
- Engineering Biosensors by Introducing Fluorescent Allosteric Signal Transducers: Construction of a Novel Glucose SensorJournal of the American Chemical Society, 1998
- Glucose oxidase: an ideal enzymeBiosensors and Bioelectronics, 1992
- Interference in glucose oxidase-peroxidase blood glucose methodsClinica Chimica Acta, 1972