Derby intramedullary nail: Further biomechanical comparison
Authors:
- D.J. PrattDPD.J. Pratt
- G. PapagiannopoulosGPG. Papagiannopoulos
- P.H. ReesPRP.H. Rees
- 1 January 1987
- journal article
- research article
- Published by IOP Publishing in Journal of Biomedical Engineering
- Vol. 9 (1) , 84-87
Abstract
This paper is the second part of a study into the mechanical effectiveness of a new intramedullary femoral nail (the Derby nail). The results of three point bending tests have shown that the Derby nail is stronger and stiffer than both the K and Zickel nails and offers advantages over the AO plate, despite the latter's higher load carrying ability when used on the compressively loaded bone face. Previous work by the authors has shown the Derby nail to be superior in torsional loading and it is felt that this intramedullary device offers sound clinical advantages over the other designs, this being confirmed by extensive clinical trials.Keywords
This publication has 11 references indexed in Scilit:
- Medullary femoral nailing of pathological fractures using the Derby nail—a preliminary report of 22 casesInjury, 1986
- Derby intramedullary nail — A biomechanical comparisonJournal of Biomedical Engineering, 1985
- Plate and bone stresses for single- and double-plated femoral fracturesJournal of Biomechanics, 1981
- A biomechanical study of internal fixation of the tibial shaftJournal of Biomechanics, 1977
- An interdisciplinary approach to evaluate the effect of internal fixation plate on long bone remodelingJournal of Biomechanics, 1977
- Ultimate properties of intramedullary nailsInjury, 1972
- The Rigidity of Fracture Immobilization with PlatesActa Orthopaedica, 1967
- Rigidity of Immobilization of Oblique FracturesActa Orthopaedica, 1965
- Rigidity of Immobilization of Transverse FracturesActa Orthopaedica, 1962
- PRINCIPLES OF INTERNAL FIXATION WITH PLATES AND SCREWSArchives of Surgery, 1952