Identification performance of MALDI-ToF-MS upon mono- and bi-microbial cultures is cell number and culture proportion dependent
Open Access
- 5 September 2019
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 411 (26) , 7027-7038
Abstract
Biotyping using matrix-assisted laser desorption ionization-time of flight (MALDI-ToF) mass spectroscopy (MS) has revolutionized microbiology by allowing clinicians and scientists to rapidly identify microbes at genus and species levels. The present study extensively assesses the suitability and reliability of MALDI-ToF biotyping of 14 different aerobic and anaerobic bacterial species as pure and mixed cultures. Reliable identification at species level was possible from biomaterial of older colonies and even frozen biomaterial, although this was species dependent. Using standard instrument settings and direct application of biomaterial onto the MALDI-ToF target plates, it was determined that the cell densities necessary for completely reliable identification of pure cultures varied between 2.40 × 108 and 1.10 × 1010 viable cell counts (VCCs) per mL, depending on the species. Evaluation of the mixed culture algorithm of the Bruker Biotyper® software showed that the performance of the algorithm depends greatly on the targeted species, on their phylogenetic distance, and on their ratio of VCC per mL in the mixed culture. Hence, the use of MALDI-ToF-MS with incorporation of the mixed culture algorithm of the software is a useful pre-screening tool for early identification of contaminants, but due to the great variability in performance between different species and the usually unknown percentage of the possible contaminant in the mixture, it is advisable to combine this method with other microbiology methods.Keywords
Funding Information
- 4D Pharma Research Ltd.
This publication has 29 references indexed in Scilit:
- Optimizing Identification of Clinically Relevant Gram-Positive Organisms by Use of the Bruker Biotyper Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry SystemJournal of Clinical Microbiology, 2013
- Species Identification of Clinical Prevotella Isolates by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2012
- Direct Matrix-Assisted Laser Desorption Ionization Time-of-Flight Mass Spectrometry Improves Appropriateness of Antibiotic Treatment of BacteremiaPLOS ONE, 2012
- The sensitivity of direct identification from positive BacT/ALERT™ (bioMérieux) blood culture bottles by matrix-assisted laser desorption ionization time-of-flight mass spectrometry is lowClinical Microbiology and Infection, 2011
- Direct Identification of Urinary Tract Pathogens from Urine Samples by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass SpectrometryJournal of Clinical Microbiology, 2010
- Performance of Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry for Identification of Bacterial Strains Routinely Isolated in a Clinical Microbiology LaboratoryJournal of Clinical Microbiology, 2010
- Comparison of Two Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Methods with Conventional Phenotypic Identification for Routine Identification of Bacteria to the Species LevelJournal of Clinical Microbiology, 2010
- Ongoing Revolution in Bacteriology: Routine Identification of Bacteria by Matrix‐Assisted Laser Desorption Ionization Time‐of‐Flight Mass SpectrometryClinical Infectious Diseases, 2009
- Highly Efficient Classification and Identification of Human Pathogenic Bacteria by MALDI-TOF MSMolecular & Cellular Proteomics, 2008
- Acetate Utilization and Butyryl Coenzyme A (CoA):Acetate-CoA Transferase in Butyrate-Producing Bacteria from the Human Large IntestineApplied and Environmental Microbiology, 2002