Effect of an asymmetric flow disturber on an ultrasonic flowmeter
- 4 December 2019
- journal article
- research article
- Published by Walter de Gruyter GmbH in TM - Technisches Messen
- Vol. 87 (1) , 3-17
Abstract
An ultrasonic flowmeter used in custody-transfer heat metering applications is subject to several test applications for approval. A flow disturbance test with an asymmetric swirl generator upstream of the device is performed to evaluate its accuracy with and without the swirl generator. This standard asymmetric swirl generator is designed to reproduce the behaviour of applications in the field, such as an out of plane 90° double bend. To assess the compliance of the already approved device (Endress+Hauser Prosonic Flow E Heat) for heat metering applications with the standard asymmetric swirl generator, extensive Computational Fluid Dynamics (CFD) simulations are performed. The steady and transient CFD simulations are carried out on a High-Performance Computer (HPC) for several volume flows. With the developed automated simulation method, a virtual calibration of the device takes place. The calibration curves for the cases of a straight pipe, and an asymmetric flow disturber mounted upstream of the flowmeter are attained from experiments and simulations. The agreement of experiments and simulations is discussed and physical insight for the behaviour of the flow disturber and the flowmeter is gained.Keywords
This publication has 11 references indexed in Scilit:
- Computation of Turbulent Flow in a Rotating Pipe using the Elliptic Blending Reynolds Stress Model2016
- A robust k−ε−/k elliptic blending turbulence model applied to near-wall, separated and buoyant flowsInternational Journal of Heat and Fluid Flow, 2012
- Detached-Eddy SimulationAnnual Review of Fluid Mechanics, 2009
- A hybrid RANS-LES approach with delayed-DES and wall-modelled LES capabilitiesInternational Journal of Heat and Fluid Flow, 2008
- Ultrasonic flowmeters: Half-century progress report, 1955–2005Ultrasonics, 2006
- A synthetic-eddy-method for generating inflow conditions for large-eddy simulationsInternational Journal of Heat and Fluid Flow, 2006
- Elliptic blending model: A new near-wall Reynolds-stress turbulence closurePhysics of Fluids, 2002
- A new k-ϵ eddy viscosity model for high reynolds number turbulent flowsComputers & Fluids, 1995
- On transition in a pipe. Part 1. The origin of puffs and slugs and the flow in a turbulent slugJournal of Fluid Mechanics, 1973
- The velocity and temperature distribution in one-dimensional flow with turbulence augmentation and pressure gradientInternational Journal of Heat and Mass Transfer, 1969