Comparison of ultra-low dose chest CT scanning protocols for the detection of pulmonary nodules: a phantom study
Authors:
- Gianluca MilaneseGMGianluca Milanese
- Mario SilvaMSMario Silva
- Thomas FrauenfelderThomas Frauenfelder
- Matthias EberhardMEMatthias Eberhard
- Federica SabiaFSFederica Sabia
- Chiara MartiniChiara Martini
- Alfonso MarchianòAMAlfonso Marchianò
- Mathias ProkopMPMathias Prokop
- Nicola SverzellatiNSNicola Sverzellati
- Ugo PastorinoUPUgo Pastorino
- 1 May 2019
- journal article
- research article
- Published by SAGE Publications in Tumori Journal
- Vol. 105 (5) , 394-403
Abstract
Purpose: To test ultra-low-dose computed tomography (ULDCT) scanning protocols for the detection of pulmonary nodules (PN). Methods: A chest phantom containing 19 solid and 11 subsolid PNs was scanned on a third-generation dual-source computed tomography (CT) scanner. Five ULDCT scans (Sn100kVp and 120, 70, 50, 30, and 20 reference mAs, using tube current modulation), reconstructed with iterative reconstruction (IR) algorithm at strength levels 2, 3, 4, and 5, were compared with standard CT (120kVp, 150 reference mAs, using tube current modulation). PNs were subjectively assessed according to a 4-point scale: 0, nondetectable nodule; 1, detectable nodule, very unlikely to be correctly measured; 2, detectable nodule, likely to be correctly measured; 3, PN quality equal to standard of reference. PN scores were analysed according to the Lung Imaging Reporting and Data System (Lung-RADS), simulating detection of nodules at baseline and incidence screening round. Results: For the baseline round, there were 17 Lung-RADS 2, 4 Lung-RADS 3, 8 Lung-RADS 4A, and 1 Lung-RADS 4B PNs. They were detectable in any ULDCT protocol, with the exception of 1 nondetectable part-solid nodule in 1 scanning protocol (120 reference mAs; IR strength: 3). For the incidence round, there were 4 Lung-RADS 2, 14 Lung-RADS 3, 2 Lung-RADS 4A, and 10 Lung-RADS 4B PNs. Ten were nondetectable in at least one ULDCT dataset; however, they were at least detectable in ULDCT with 70 reference mAs (IR strength: 4 and 5). Conclusions: ULDCT scanning protocols allowing the detection of PNs can be proposed for the purpose of lung cancer screening.Keywords
This publication has 31 references indexed in Scilit:
- Chest CT using spectral filtration: radiation dose, image quality, and spectrum of clinical utilityEuropean Radiology, 2014
- Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screeningThe Lancet Oncology, 2014
- Update in the Evaluation of the Solitary Pulmonary NoduleRadioGraphics, 2014
- Ultralow-Dose Chest Computed Tomography for Pulmonary Nodule DetectionInvestigative Radiology, 2014
- Image quality assessment of ultra low-dose chest CT using sinogram-affirmed iterative reconstructionEuropean Radiology, 2014
- Computer-Aided Segmentation and Volumetry of Artificial Ground-Glass Nodules at Chest CTAmerican Journal of Roentgenology, 2013
- Definition of a Positive Test Result in Computed Tomography Screening for Lung CancerAnnals of Internal Medicine, 2013
- Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination: preliminary observationsEuropean Radiology, 2012
- Benefits and Harms of CT Screening for Lung CancerJAMA, 2012
- Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic ScreeningThe New England journal of medicine, 2011