Clinical evaluation of low-power laser and a desensitizing agent on dentin hypersensitivity
- 4 October 2013
- journal article
- research article
- Published by Springer Nature in Lasers in Medical Science
- Vol. 30 (2) , 823-829
Abstract
The aim of this randomized, longitudinal clinical study was to evaluate different protocols for dentin hypersensitivity treatment with low-power laser at different dosages, desensitizing agent, and associations, for a period of 6 months. After analysis of the inclusion and exclusion criteria of volunteer participants, those who present pain resulting from non-carious cervical lesions were selected. Twenty-seven patients participated in the study, and 55 lesions were recorded. The lesions were divided into five groups (n = 11), treated, and evaluated: G1: Gluma Desensitizer (Heraeus); G2: low-power laser (Photon Lase, DMC) at low dose (three vestibular points and one apical point of irradiation: 30 mW, 10 J/cm2, 9 s per point with wavelength of 810 nm), three sessions were performed with an interval of 72 h between them; G3: low-power laser at high dose (application at one cervical and one apical point: 100 mW, 90 J/cm2, 11 s per point with wavelength of 810 nm), three sessions were performed with an interval of 72 h between irradiations; G4: low-power laser at low dose + Gluma Desensitizer; and G5: low-power laser at high dose + Gluma Desensitizer, the level of sensitivity of each volunteer was evaluated with a visual analog scale of pain (VAS) with the use of air from a triple syringe and exploration with a probe after time intervals of 5 min, 1 week, and 1, 3, and 6 months after treatment. Data were collected and subjected to statistical analysis. Kolmogorov–Smirnov test was used to verify the distribution of the data, and nonparametric Kruskal–Wallis and Friedman tests were performed for comparison among the experimental groups and time intervals studied, respectively. Statistically significant differences between the studied time intervals (p < 0.05) were detected. From the difference in pain, it was observed that for both stimuli, the protocol with the Gluma desensitizing agent presented immediate effects of pain reduction. For low-level lasers, it was observed that there were distinct effects for the different doses; however, both were efficient in reducing pain up to the 6 months of clinical follow-up. Therefore, it could be concluded that all the desensitizing protocols were effective in reducing dentin hypersensitivity, but with different effects. The combination of protocols is an interesting alternative in the treatment of cervical dentin hypersensitivity.Keywords
This publication has 37 references indexed in Scilit:
- Comparative Evaluation of the Effects of Nd:YAG Laser and a Desensitizer Agent on the Treatment of Dentin Hypersensitivity: A Clinical StudyPhotomedicine and Laser Surgery, 2013
- In vitro effects of Er,Cr:YSGG laser on dentine hypersensitivity. Dentine permeability and scanning electron microscopy analysisLasers in Medical Science, 2011
- Effects of the Combined Desensitizing Dentifrice and Diode Laser Therapy in the Treatment of Desensitization of Teeth with Gingival RecessionPhotomedicine and Laser Surgery, 2010
- Dentine hypersensitivity: preventive and therapeutic approaches to treatmentPeriodontology 2000, 2008
- Comparative study in desensitizing efficacy using the GaAlAs laser and dentin bonding agentJournal of Dentistry, 2008
- Clinical Evaluation of Three Desensitizing Agents in Relieving Dentin HypersensitivityOperative Dentistry, 2007
- Effect of GaAIAs Laser on Reactional Dentinogenesis Induction in Human TeethPhotomedicine and Laser Surgery, 2006
- Aetiology, prevalence and clinical features of cervical dentine sensitivityJournal of Oral Rehabilitation, 1997
- Dentinal Tubule Occlusion and Root HypersensitivityJournal of Periodontology, 1991
- Lasers in dentistryBritish Dental Journal, 1991