Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV
Authors:
- J. Lerendegui-MarcoJLJ. Lerendegui-Marco
- C. GuerreroCGC. Guerrero
- E. MendozaEME. Mendoza
- J. M. QuesadaJQJ. M. Quesada
- K. EberhardtKEK. Eberhardt
- A. R. JunghansAJA. R. Junghans
- V. AlcayneVAV. Alcayne
- V. BabianoVBV. Babiano
- O. AberleOAO. Aberle
- J. AndrzejewskiJAJ. Andrzejewski
- L. AudouinLAL. Audouin
- M. BacakMBM. Bacak
Open Access
- 20 February 2026
- journal article
- Published by Springer Nature in The European Physical Journal A
- Vol. 62 (2)
Abstract
Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $$^{242}$$ Pu, the Nuclear Energy Agency (NEA) recommends 8–12% accuracy in the fast energy region (2–500 keV), compared to the current uncertainty of 35%. Moreover, integral experiments and previous measurements suggest the evaluated $$^{242}$$ Pu(n, $$\gamma $$ ) cross section is overestimated, particularly in the JEFF-3.3 library, which shows a 14% overestimation between 1 keV and 1 MeV. Recent measurements from LANSCE reported a 20–30% reduction in the 1–40 keV range relative to evaluations. To solve these discrepancies, the $$^{242}$$ Pu(n, $$\gamma $$ ) cross section was measured from 1 to 600 keV at CERN n_TOF-EAR1 facility using a 95(4) mg $$^{242}$$ Pu target, enriched to 99.959%. Gamma rays from neutron capture were detected with an array of $$\hbox {C}_6\hbox {D}_6$$ scintillators and a novel application of the Pulse Height Weighting Technique was employed. The resulting cross section presents a systematic uncertainty between 8 and 12%, reducing the current uncertainties of 35% and achieving the accuracy requested by the NEA. Analysis using FITACS produced average resonance parameters, consistent with the analysis of the resolved resonance region. Our data align well with Wisshak and Käeppeler, and are 10–14% lower than JEFF-3.3 in the 1–250 keV range, helping to achieve consistency with integral benchmarks. At higher energies, our results are in reasonable agreement with ENDF/B-VIII.1 and JEFF-3.3. In contrast, DANCE results appear to underestimate the cross section by a factor of 2–3 above a few keV.
Keywords
All Related Versions
Funding Information
- Universidad de Sevilla (V Plan Propio de Investigación)
- Ministerio de Economía y Competitividad (FPA2013-45083-P)
- Ministerio de Economía y Competitividad (FPA2014-53290-C2-2-P)
- Ministerio de Economía y Competitividad (FPA2016-77689-C2-1-R)
- Hrvatska Zaklada za Znanost (Project IP-2022-10-3878)
- Conselleria de Innovación, Universidades, Ciencia y Sociedad Digital, Generalitat Valenciana (Postdoctoral grant CIAPOS/2022/020)
- FP7 Energy (CHANDA (Grant No. 605203))
- FP7 Energy (NEUTANDALUS (Grant No. 334315))
- Bundesministerium für Bildung, Wissenschaft, Forschung und Technologie (Contract number 03NUK13A)
This publication has 52 references indexed in Scilit:
- ENDF/B-VIII.0: The 8 th Major Release of the Nuclear Reaction Data Library with CIELO-project Cross Sections, New Standards and Thermal Scattering DataNuclear Data Sheets, 2018
- General Description of Fission Observables: GEF Model CodeNuclear Data Sheets, 2016
- Measurement of the 242Pu(n,f) Cross Section at the CERN n_TOF FacilityNuclear Data Sheets, 2014
- International Evaluation of Neutron Cross Section StandardsNuclear Data Sheets, 2009
- RIPL – Reference Input Parameter Library for Calculation of Nuclear Reactions and Nuclear Data EvaluationsNuclear Data Sheets, 2009
- The data acquisition system of the neutron time-of-flight facility n_TOF at CERNNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Time–energy relation of the n_TOF neutron beam: energy standards revisitedNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- New experimental validation of the pulse height weighting technique for capture cross-section measurementsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- A low background neutron flux monitor for the n_TOF facility at CERNNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2004
- Absolute neutron capture yield calibrationNuclear Instruments and Methods, 1979