The correspondence between coronary arterial wall strain and histology in a porcine model of atherosclerosis
Authors:
- Hui ZhuHZHui Zhu
- Morton H FriedmanMFMorton H Friedman
- 1 September 2009
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 54 (18) , 5625-5641
Abstract
Atherosclerotic plaque rupture is the leading cause of mortality in cardiovascular disease. Intravascular ultrasound (IVUS) imaging is a powerful clinical technique that provides real-time cross-sectional images of the arterial wall and atherosclerotic plaques. However, it does not provide sufficient information about the histological composition of plaques to characterize their vulnerability. Arterial wall strain measurements may provide insights into plaque composition and vulnerability, complementing the information directly available in the IVUS echogram. We have developed a method to measure the transverse arterial wall strain tensor in response to luminal pressure change, by registering IVUS images acquired at different pressures. This method has been validated by using IVUS images with simulated motion and IVUS images of a vessel phantom. In this study, we further evaluate the method by assessing the correspondence of the calculated strain distribution and the histological composition of atherosclerotic coronary arteries from Sinclair miniature pigs following 12 months of a high fat diet. The images were acquired in situ using a clinical IVUS system and under computer-controlled pressurization. After image acquisition, the artery segments were fixed for histology to identify plaque components. The strain distributions were aligned with the corresponding histological sections. The stiffness of various components of the lesion, inferred from the wall strain distribution, was consistent with the tissue composition seen in the histological cross-sections. These findings suggest that strain measurements from IVUS are promising for assessing plaque vulnerability.Keywords
This publication has 53 references indexed in Scilit:
- Improving IVUS palpography by incorporation of motion compensation based on block matching and optical flowIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2008
- Accuracy in Prediction of Catheter Rotation in IVUS With Feature-Based Optical Flow—A Phantom StudyIEEE Transactions on Information Technology in Biomedicine, 2008
- Pathogenesis of AtherosclerosisJACC, 2006
- Identification of Atherosclerotic Plaque Components With Intravascular Ultrasound Elastography In VivoCirculation, 2002
- Morphological and mechanical information of coronary arteries obtained with intravascular elastography. Feasibility study in vivoEuropean Heart Journal, 2002
- Axial strain imaging of intravascular data: results on polyvinyl alcohol cryogel phantoms and carotid arteryUltrasound in Medicine & Biology, 2001
- Characterization of Plaque Components With Intravascular Ultrasound Elastography in Human Femoral and Coronary Arteries In VitroCirculation, 2000
- Clinical application and image interpretation in intracoronary ultrasoundEuropean Heart Journal, 1998
- Elastic and Acoustic Properties of Vessel Mimicking Material for Elasticity ImagingUltrasonic Imaging, 1997
- Intravascular elasticity imaging using ultrasound: Feasibility studies in phantomsUltrasound in Medicine & Biology, 1997