Technical assessment of a prototype cone‐beam CT system for imaging of acute intracranial hemorrhage
Open Access
- 29 September 2016
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 43 (10) , 5745-5757
Abstract
Purpose: A cone‐beam CT scanner has been developed for detection and monitoring of traumatic brain injury and acute intracranial hemorrhage (ICH) at the point of care. This work presents a technical assessment of imaging performance and dose for the scanner in phantom and cadaver studies as a prerequisite to clinical translation.Methods: The scanner incorporates a compact, rotating‐anode x‐ray source and a flat‐panel detector (43 × 43 cm2) on a mobile U‐arm gantry with source‐axis distance = 550 mm and source‐detector distance = 1000 mm. Central and peripheral doses were measured in 16 cm diameter CTDI phantoms using a 0.6 cm3 Farmer ionization chamber for various scan techniques and as a function of longitudinal position, including out of field. Spatial resolution, contrast, noise, and image uniformity were assessed in quantitative and anthropomorphic head phantoms. Two reconstruction protocols were evaluated, including filtered backprojection (FBP) for high‐resolution bone imaging and penalized weighted least squares (PWLS) reconstruction for low‐contrast soft tissue (ICH) visualization. A fresh cadaver was imaged with and without simulated ICH using the scanner as well as a diagnostic multidetector CT (MDCT) scanner using a standard head protocol. Images were interpreted by a fellowship‐trained neuroradiologist for imaging tasks of ICH detection, gray‐white‐CSF differentiation, detection of midline shift, and fracture detection.Results: The nominal scan protocol involved 720 projections acquired over a 360° orbit at 100 kV and 216 mAs, giving a dose (weighted CTDI) of 22.8 mGy (∼1.2 mSv effective dose). Out‐of‐field dose decreased to <10% within 6 cm of the field edge (approximate to the thyroid position). Image uniformity demonstrated <1% variation between the edge of the field (near the cranium) and center of the image. The high‐resolution FBP reconstruction protocol showed ∼0.9 mm point spread function (PSF) full‐width at half‐maximum (FWHM). The smooth PWLS reconstruction protocol yielded ∼1.2 mm PSF FWHM and contrast‐to‐noise ratio exceeding 5.7 in ∼50 HU spherical ICH, resulting in conspicuous depiction of ICH down to ∼2 mm (the smallest diameter investigated). Cadaver images demonstrated good differentiation of brain and CSF (sufficient, but inferior to MDCT, recognizing that the CBCT dose was one‐third that of MDCT), excellent visualization of cranial sutures and fracture (potentially superior to MDCT), clear detection of midline shift, and conspicuous detection of ICH.Conclusions: Technical assessment of the prototype demonstrates dose characteristics and imaging performance consistent with point‐of‐care detection and monitoring of head injury—most notably, conspicuous detection of ICH—and supports translation of the system to clinical studies.Keywords
Funding Information
- Carestream Health (Carestream Health Inc.)
- Carestream Health
- Carestream Health
This publication has 69 references indexed in Scilit:
- Technical assessment of a cone‐beam CT scanner for otolaryngology imaging: Image quality, dose, and technique protocolsMedical Physics, 2012
- Cone-beam CT with a flat-panel detector: From image science to image-guided surgeryNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2011
- Intrahospital Transport to the Radiology Department: Risk for Adverse Events, Nursing Surveillance, Utilization of a MET, and Practice ImplicationsJournal of Radiology Nursing, 2011
- Robotic Digital Subtraction Angiography Systems Within the Hybrid Operating RoomNeurosurgery, 2011
- Benefit and accuracy of intraoperative 3D-imaging after pedicle screw placement: a prospective study in stabilizing thoracolumbar fracturesEuropean Spine Journal, 2009
- Cone‐beam volume CT breast imaging: Feasibility studyMedical Physics, 2002
- Utility of Perfusion-Weighted CT Imaging in Acute Middle Cerebral Artery Stroke Treated With Intra-Arterial Thrombolysis:Stroke, 2001
- Radiation doses to infants and adults undergoing head CT examinationsMedical Physics, 2001
- Pathobiology of traumatically induced axonal injury in animals and manAnnals of Emergency Medicine, 1993
- A local update strategy for iterative reconstruction from projectionsIEEE Transactions on Signal Processing, 1993