Pressure gradients in the brain in an experimental model of hydrocephalus
Authors:
- Richard D. PennRPRichard D. Penn
- Max C. LeeMLMax C. Lee
- Andreas A. LinningerALAndreas A. Linninger
- Keith MieselKMKeith Miesel
- Steven Ning LuSLSteven Ning Lu
- Lee StylosLSLee Stylos
- 1 June 2005
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 102 (6) , 1069-1075
Abstract
Object. The goal of this investigation was to establish whether pressure gradients exist between the ventricles, brain tissue, and subarachnoid space when acute or chronic hydrocephalus develops. Such gradients are hypothesized by many models of hydrocephalus, but considerable controversy continues about their existence. Methods. A stereotactic frame was used for surgery in dogs to implant pressure sensors within the right lateral ventricle, the frontal lobe, and forward in the subarachnoid space. The dogs were allowed to recover for 10 to 14 days postoperatively. Then, 800 mg of sterile kaolin in water was injected into the cisterna magna region by using a percutaneous approach. Both real-time and long-term intracranial pressures were measured. Of the six dogs, one experienced an intracranial hemorrhage, one dog displayed status epilepticus after a second injection of kaolin and was killed, one experienced acute hydrocephalus, and three experienced mild chronic hydrocephalus. No consistent pressure differences were found in any dog between the ventricle, brain, and subarachnoid space before kaolin administration or afterward when hydrocephalus developed. In addition, no pulse pressure gradients occurred between the brain and the ventricle or subarachnoid space. Conclusions. Precise monitoring of pressure before and during the development of hydrocephalus did not detect pressure gradients between the ventricle, brain, and subarachnoid space. This was true for long-term measurements over weeks and for real-time measurements that allowed accurate assessment of pulse pressures. Theories predicting pressure gradients greater than the resolution of these sensors (0.5 mm Hg) across brain tissue have to be reevaluated in light of these findings.Keywords
This publication has 10 references indexed in Scilit:
- Pulsatile Cerebrospinal Fluid Dynamics in the Human BrainIEEE Transactions on Biomedical Engineering, 2005
- A Model of Pulsations in Communicating HydrocephalusPediatric Neurosurgery, 2002
- There Is No Transmantle Pressure Gradient in Communicating or Noncommunicating HydrocephalusNeurosurgery, 2002
- A Model of Intracranial PulsationsPediatric Neurosurgery, 2001
- Long-term testing of an intracranial pressure monitoring deviceJournal of Neurosurgery, 2000
- Effects of Brain Ventricular Shape on Periventricular Biomechanics: A Finite-element AnalysisNeurosurgery, 1999
- Phase Contrast Cine Magnetic Resonance Imaging: Normal Cerebrospinal Fluid Oscillation and Applications to HydrocephalusNeurosurgery Clinics of North America, 1993
- Progressive ventricular enlargement in cats in the absence of transmantle pressure gradientsJournal of Neurosurgery, 1987
- Experimental feline hydrocephalusJournal of Neurosurgery, 1985
- Experimental normal-pressure hydrocephalus is accompanied by increased transmantle pressureJournal of Neurosurgery, 1984