Aberrator integration error in adaptive imaging
Authors:
- G.E. TraheyGTG.E. Trahey
- 1 July 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 44 (4) , 780-791
Abstract
Tissue speed of sound inhomogeneities cause significant degradation of medical ultrasound images. In some cases these inhomogeneities may be modeled as a thin time delay screen located at the face of the transducer. The effects of such near-field aberrations can be reduced by adding compensating time delays to the normal system focusing delays. Unfortunately array elements are generally large in at least one dimension when compared to variations in the aberrator, thus correction of the mean time delay on an element leaves residual variations in the time delay profile across that element. This paper presents theoretical expressions and simulation results describing the magnitude of this aberrator integration error. Simulations results are also presented which show the distortion of received pulses and degradation of point spread functions which results from aberrator integration error. These results indicate that aberrator integration error may be the dominant source of error in the implementation of adaptive imaging techniques and in phase aberration measurements. Thus, correction of near-field aberrations may be significantly more difficult than previously suspected.Keywords
This publication has 12 references indexed in Scilit:
- A comparison of ultrasonic wavefront distortion and compensation in one-dimensional and two-dimensional aperturesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Measurement and correction of ultrasonic pulse distortion produced by the human breastThe Journal of the Acoustical Society of America, 1995
- A fundamental limit on delay estimation using partially correlated speckle signalsIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1995
- Waveform aberrations in an animal model1994
- Two Dimensional Ultrasonic Beam Distortion in the Breast: In Vivo Measurements and EffectsUltrasonic Imaging, 1992
- Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992
- The van Cittert–Zernike theorem in pulse echo measurementsThe Journal of the Acoustical Society of America, 1991
- Preliminary InvestigationsInvestigative Radiology, 1990
- Direct estimation of aberrating delays in pulse-echo imaging systemsThe Journal of the Acoustical Society of America, 1990
- Phase-aberration correction using signals from point reflectors and diffuse scatterers: basic principlesIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1988