New methods of data calibration for high power-aperture lidar
- 22 March 2013
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 21 (6) , 7768-7785
Abstract
For high power-aperture lidar sounding of wide atmospheric dynamic ranges, as in middle-upper atmospheric probing, photomultiplier tubes’ (PMT) pulse pile-up effects and signal-induced noise (SIN) complicates the extraction of information from lidar return signal, especially from metal layers’ fluorescence signal. Pursuit for sophisticated description of metal layers’ characteristics at far range (80~130km) with one PMT of high quantum efficiency (QE) and good SNR, contradicts the requirements for signals of wide linear dynamic range (i.e. from approximate 102 to 108 counts/s). In this article, Substantial improvements on experimental simulation of Lidar signals affected by PMT are reported to evaluate the PMTs’ distortions in our High Power-Aperture Sodium LIDAR system. A new method for pile-up calibration is proposed by taking into account PMT and High Speed Data Acquisition Card as an Integrated Black-Box, as well as a new experimental method for identifying and removing SIN from the raw Lidar signals. Contradiction between the limited linear dynamic range of raw signal (55~80km) and requirements for wider acceptable linearity has been effectively solved, without complicating the current lidar system. Validity of these methods was demonstrated by applying calibrated data to retrieve atmospheric parameters (i.e. atmospheric density, temperature and sodium absolutely number density), in comparison with measurements of TIMED satellite and atmosphere model. Good agreements are obtained between results derived from calibrated signal and reference measurements where differences of atmosphere density, temperature are less than 5% in the stratosphere and less than 10K from 30km to mesosphere, respectively. Additionally, approximate 30% changes are shown in sodium concentration at its peak value. By means of the proposed methods to revert the true signal independent of detectors, authors approach a new balance between maintaining the linearity of adequate signal (20-110km) and guaranteeing good SNR (i.e. 104:1 around 90km) without debasing QE, in one single detecting channel. For the first time, PMT in photon-counting mode is independently applied to subtract reliable information of atmospheric parameters with wide acceptable linearity over an altitude range from stratosphere up to lower thermosphere (20-110km).Keywords
This publication has 19 references indexed in Scilit:
- Temperature lidar measurements from 1 to 105 km altitude using resonance, Rayleigh, and Rotational Raman scatteringAtmospheric Chemistry and Physics, 2004
- A survey of the signal-induced noise in photomultiplier detection of wide dynamics luminous signalsReview of Scientific Instruments, 1996
- Stratospheric temperature measurements by two collocated NDSC lidars during UARS validation campaignJournal of Geophysical Research: Atmospheres, 1996
- Signal linearity, gain stability, and gating in photomultipliers: application to differential absorption lidarsApplied Optics, 1995
- Differential absorption lidar system for routine monitoring of tropospheric ozoneApplied Optics, 1994
- Correction for nonlinear photon-counting effects in lidar systemsApplied Optics, 1993
- Improvement on lidar data processing for stratospheric aerosol measurementsApplied Optics, 1987
- Large scale laser radar for measuring aerosol distribution over a wide areaApplied Optics, 1985
- Testing the Linearity of Response of Gated Photomultipliers in Wide Dynamic Range Laser Radar SystemsIEEE Transactions on Nuclear Science, 1975
- 2.3 - Performance limits and design procedure for all-weather terrestrial rangefindersIEEE Journal of Quantum Electronics, 1967