Repair of Peripheral Nerve Defects in Rabbits Using Keratin Hydrogel Scaffolds
Authors:
- 1 June 2011
- journal article
- research article
- Published by SAGE Publications in Tissue Engineering Part A
- Vol. 17 (11-12) , 1499-1505
Abstract
Entubulation of transected nerves using bioabsorbable conduits is a promising alternative to sural nerve autografting, but full functional recovery is rarely achieved. Numerous studies have suggested that scaffold-based conduit fillers may promote axon regeneration, but no neuroinductive biomaterial filler has been identified. We previously showed that a nerve guide filled with keratin hydrogel actively stimulates regeneration in a mouse model, and results in functional outcomes superior to empty conduits at early time points. The goal of the present study was to develop a peripheral nerve defect model in a rabbit and assess the effectiveness of a keratin hydrogel filler. Although repairs with keratin-filled conduits were not as consistently successful as autograft overall, the use of keratin resulted in a significant improvement in conduction delay compared to both empty conduits and autograft, as well as a significant improvement in amplitude recovery compared to empty conduits when measurable regeneration did occur. Taking into account all study animals (i.e., regenerated and nonregenerated), histological assessment showed that keratin-treated nerves had significantly greater myelin thickness than empty conduits. These data support the findings of our earlier study and suggest that keratin hydrogel fillers have the potential to be used clinically to improve conduit repair.Keywords
This publication has 30 references indexed in Scilit:
- Motor nerve regeneration across a conduitMicrosurgery, 2008
- Maximum Number of Collaterals Developed by One Axon during Peripheral Nerve Regeneration and the Influence of That Number on Reinnervation EffectsEuropean Neurology, 2007
- Mechanisms of Disease: what factors limit the success of peripheral nerve regeneration in humans?Nature Clinical Practice Neurology, 2006
- A Prospective Clinical Evaluation of Biodegradable Neurolac Nerve Guides for Sensory Nerve Repair in the HandThe Journal of Hand Surgery, 2005
- Surgical repair of brachial plexus injuryJournal of Neurosurgery, 2004
- Collagen- and laminin-containing gels impede peripheral nerve regeneration through semipermeable nerve guidance channelsExperimental Neurology, 1987
- Peripheral nerve regeneration with entubulation repair: Comparison of biodegradeable nerve guides versus polyethylene tubes and the effects of a laminin-containing gelExperimental Neurology, 1987
- Increased rate of peripheral nerve regeneration using bioresorbable nerve guides and a laminin-containing gelExperimental Neurology, 1985
- Spatial‐Temporal progress of peripheral nerve regeneration within a silicone chamber: Parameters for a bioassayJournal of Comparative Neurology, 1983
- Nerve regeneration and Schwann cell basal lamina: Observations of the long-term regeneration.Archivum histologicum japonicum, 1983