Cirq® Robotic Assistance for Minimally Invasive C1-C2 Posterior Instrumentation: Report on Feasibility and Safety
Authors:
- 25 July 2020
- journal article
- research article
- Published by Wolters Kluwer Health in Operative Neurosurgery
- Vol. 19 (6) , 730-734
Abstract
BACKGROUND: Accurate screw placement remains very challenging especially in the upper cervical spine. OBJECTIVE: To present our first experience of a percutaneous posterior C1-C2 fixation for a traumatic fracture. METHODS: This is a case report of a non-neurological patient, harboring a type II odontoid fracture. She underwent a posterior percutaneous fixation using Cirq® Robotic Assistance coupled to the AIRO® intraoperative computed tomography (iCT)-scan and BrainLab® navigation system (all by BrainLab AG). Routine CT was performed on postoperative day 2 to evaluate pedicle screw placement. The effective dose was calculated. RESULTS: The C1-C2 posterior percutaneous fixation was performed with cannulated VERTEX® Reconstruction System (Medtronic). Overall, 4 screws were placed. All of them were rated as acceptable (100%). Radiation dose received by the patient was 4.13 mSv. Radiation dose received by the surgical staff was 0 mSv. Postoperative course was excellent. CONCLUSION: Posterior percutaneous fixation using Cirq® Robotic Assistance coupled with iCT navigation system is a major innovation that can improve pedicle screw positioning's accuracy with acceptable patient radiation and reduced surgical team exposure.Keywords
This publication has 18 references indexed in Scilit:
- Type II Odontoid Fractures of the Cervical SpineSpine, 2011
- Perioperative course and accuracy of screw positioning in conventional, open robotic-guided and percutaneous robotic-guided, pedicle screw placementEuropean Spine Journal, 2011
- Clinical Acceptance and Accuracy Assessment of Spinal Implants Guided With SpineAssist Surgical RobotSpine, 2010
- Morbidity and Mortality Related to Odontoid Fracture Surgery in the Elderly PopulationSpine, 2010
- Odontoid Fractures in the Elderly: Should We Operate?Journal of Trauma: Injury, Infection & Critical Care, 2010
- Anterior fixation of odontoid fractures in an elderly populationJournal of Neurosurgery: Spine, 2010
- Percutaneous Placement of Pedicle Screws in the Lumbar Spine Using a Bone Mounted Miniature Robotic SystemSpine, 2009
- Isolated Cervical Spine Fractures in the Elderly: A Deadly InjuryJournal of Trauma: Injury, Infection & Critical Care, 2008
- Odontoid Fractures in the Elderly: Dorsal C1/C2 Fusion is Superior to Halo-Vest ImmobilizationJournal of Trauma: Injury, Infection & Critical Care, 2007
- Halo-Vest Immobilization Increases Early Morbidity and Mortality in Elderly Odontoid Fractures2006