PARHELIA: Particle Filter-Based Heart Rate Estimation From Photoplethysmographic Signals During Physical Exercise
Authors:
- 25 April 2017
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 65 (1) , 189-198
Abstract
The photoplethysmographic (PPG) signal is an important source of information for estimating heart rate (HR). However, the PPG signal could be strongly contaminated by the motion artifact of the subjects, making HR estimation a particularly difficult problem. In this paper, we propose PARHELIA, a PARticle filter-based algorithm for HEart rate estimation using photopLethysmographIc signAls. The proposed method employs a particle filter, and utilizes the simultaneously recorded acceleration signals from a wrist-type sensor, to keep track of multiple HR candidates. This achieves quick recovery from incorrect HR estimations under the strong influence of the MA. Experimental results for a dataset of 12 subjects recorded during fast running showed that the average absolute estimation error was 1.17 beats per minute (BPM) whereas that of the best-known conventional method, JOSS, is 1.28 BPM. Furthermore, the estimation time of PARHELIA is 20 times shorter than JOSS.Keywords
Funding Information
- Japan Society
- Promotion of Science (JSPS) Kakenhi (15K12700)
This publication has 17 references indexed in Scilit:
- Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum ReconstructionIEEE Transactions on Biomedical Engineering, 2015
- TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical ExerciseIEEE Transactions on Biomedical Engineering, 2014
- Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filterBioMedical Engineering OnLine, 2014
- A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic BiosensorsIEEE Journal of Biomedical and Health Informatics, 2013
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Motion Artifact Reduction in Photoplethysmography Using Independent Component AnalysisIEEE Transactions on Biomedical Engineering, 2006
- Particle filters for positioning, navigation, and trackingIEEE Transactions on Signal Processing, 2002
- A tutorial on particle filters for online nonlinear/non-Gaussian Bayesian trackingIEEE Transactions on Signal Processing, 2002
- Monte Carlo Filter and Smoother for Non-Gaussian Nonlinear State Space ModelsJournal of Computational and Graphical Statistics, 1996
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986