A comparative in vitro study of a magnetostrictive and a piezoelectric ultrasonic scaling instrument

Authors:

Abstract
Background: The effects of magnetostrictive ultrasonic instruments and piezoelectric ultrasonic instruments on tooth surfaces seem to differ with regards to root debridement.Aim: The purpose of this study was to compare a magnetostrictive ultrasonic scaling instrument with a piezoelectric ultrasonic scaling instrument and a hand curette regarding time taken, calculus removal, tooth surface roughness (Ra), and SEM examination before and after instrumentation.Methods: 30 extracted human teeth with subgingival calculus were assigned to one of three treatment groups (n=10). The working force was standardised for both ultrasonic instruments at 200 g and for the curette at 500 g.Results: The results revealed that the time needed for instrumentation was 126.1±38.2 s for the curette, significantly more than for the piezoelectric ultrasonic instrument (74.1±27.6 s; ppConclusion: The piezoelectric ultrasonic scaler was more efficient than the magnetostrictive ultrasonic scaler in removing calculus but left the instrumented tooth surface rougher.

This publication has 17 references indexed in Scilit: