Molecularly imprinted polymers for on-line clean up and preconcentration of chloramphenicol prior to its voltammetric determination
Authors:
- M. L. MenaMMM. L. Mena
- L. AgüíLAL. Agüí
- P. Martinez-RuizPMP. Martinez-Ruiz
- P. Yáñez-SedeñoPYP. Yáñez-Sedeño
- A. J. ReviejoARA. J. Reviejo
- J. M. PingarrónJ. M. Pingarrón
- 3 April 2003
- journal article
- research article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 376 (1) , 18-25
Abstract
The performance of a molecularly imprinted polymer (MIP) as a selective solid-phase extraction sorbent for the clean-up and preconcentration of the antibiotic chloramphenicol is described. The MIP was prepared using chloramphenicol as the template, (diethylamino)ethyl methacrylate as the functional monomer, and ethylene glycol dimethacrylate as the cross-linking monomer, and using tetrahydrofuran as the solvent. Detection of chloramphenicol was carried out by square-wave voltammetry at electrochemically activated carbon fiber microelectrodes. Chloramphenicol was eluted from the MIP microcolumn with methanol. Different experimental variables (sample pH, eluent volume, analyte and eluent flow rates and sample volume) associated with the rebinding/elution process were optimized. For a 250 mL sample, a nominal enrichment factor of 500 was attained, and for a chloramphenicol concentration of 3.0×10−8 mol L−1 (9.7 μg L−1) a recovery of 96±4% was obtained. A range of linearity for chloramphenicol between 3.0×10−8 and 1.0×10−5 mol L−1 was obtained by loading 17 mL of analyte solutions of different concentration, eluting with 0.5 mL methanol, evaporating under a stream of nitrogen and dissolving the residue in phosphate buffer of pH 7.8. The MIP selectivity was evaluated by checking several substances with similar molecular structures to that of chloramphenicol. The applicability of the MIP for both clean up and preconcentration was demonstrated by determining chloramphenicol in ophthalmic solutions and spiked milk at different concentration levels.Keywords
This publication has 32 references indexed in Scilit:
- Molecularly imprinted polymer for metsulfuron-methyl and its binding characteristics for sulfonylurea herbicidesAnalytica Chimica Acta, 2002
- Voltammetric determination of chloramphenicol in milk at electrochemically activated carbon fibre microelectrodesAnalytica Chimica Acta, 2002
- Chloramphenicol sensor based on an in situ imprinted polymerAnalytica Chimica Acta, 1998
- Molecularly Imprinted Solid Phase Extraction of Atrazine from Beef Liver ExtractsAnalytical Chemistry, 1997
- Evaluation of a Molecular-imprinted Polymer for use in the Solid Phase Extraction of Propranolol From Biological FluidsAnalytical Communications, 1997
- Analytical Applications of Cylindrical Carbon Fiber Microelectrodes. Simultaneous Voltammetric Determination of Phenolic Antioxidants in FoodAnalytical Chemistry, 1995
- An analysis of small-molecule binding to functionalized synthetic polymers by 13C CP/MAS NMR and FT-IR spectroscopyJournal of the American Chemical Society, 1991
- Enzyme-analog-built polymers. 27. Racemic resolution of free sugars with macroporous polymers prepared by molecular imprinting. Selectivity dependence on the arrangement of functional groups versus spatial requirementsThe Journal of Organic Chemistry, 1991
- Determination of Residues of Chemotherapeutic and Antiparasitic Drugs in Food Stuffs of Animal Origin with Liquid Chromatography and UV/VIS Diode-Array DetectionJournal of Liquid Chromatography, 1988
- Chloramphenicol in the 1980sDrugs, 1984